Step 8 Connect Battery Pack, Continued
Configure Battery Backup After installing the MegaRAID controller and booting, press <Ctrl> <M>. Choose the Objects menu. Select Battery Backup. The following menu displays:
| Menu Item | Explanation |
|
| Battery Pack | PRESENT will appear if the battery pack is properly installed; |
|
|
| ABSENT if it is not. |
|
| Temperature | GOOD appears if the temperature is within the normal range. HIGH |
|
|
| appears if the module is too hot. |
|
| Voltage | GOOD appears if the voltage is within the normal range. BAD |
|
|
| appears if the voltage is out of range. |
|
| Fast | COMPLETED appears if the fast charge cycle is done. CHARGING |
|
| Charging | appears if the battery pack is charging. |
|
| No. of | This must be configured. When first installing a battery pack, set the |
|
| Cycles | Charge Cycle to 0. The screen below appears when you select No. of |
|
|
| Cycles. Choose YES to reset the number of cycles to zero. |
|
|
| After 1100 charge cycles, the life of the battery pack is assumed to |
|
|
| be over and you must replace the battery pack. |
|
|
|
|
|
64MegaRAID Enterprise 1600 Hardware Guide