DOS ASPI Driver Error Messages
Message |
| Corrective Action |
|
LSI Logic ASPI Manager has | The ASPI manager is not loaded. One of the failure |
| |
NOT been loaded. | codes listed below is displayed next. |
| |
Controller setup FAILED | Correct the condition that caused the failure. The |
| |
error code=[0xab] | failure codes are: |
| |
| 0x40 | No MegaRAID adapters found |
|
| 0x80 | Timed out waiting for interrupt to be posted |
|
| 0x81 | Timed out waiting for the MegaRAID |
|
|
| Response command. |
|
| 0x82 | Invalid command completion count. |
|
| 0x83 | Invalid completion status received. |
|
| 0x84 | Invalid command ID received. |
|
| 0x85 | No MegaRAID adapters found or no PCI |
|
|
| BIOS support. |
|
| 0x90 | Unknown Setup completion error |
|
No | The driver did not find any |
| |
located | during scanning. A SCSI device that is not a hard disk |
| |
| drive, such as a tape drive or |
| |
| attached to this SCSI channel. The SCSI ID must be |
| |
| unique for each adapter and cannot be SCSI ID 0. The |
| |
| supported SCSI IDs are 1, 2, 3, 4, 5, and 6. |
| |
'ERROR: VDS support is | The /h option is appended to driver in |
| |
*INACTIVE* for | CONFIG.SYS or this driver is used with a BIOS that |
| |
MegaRAID logical drives | is earlier than v1.10, or no logical drives are |
| |
| configured. |
| |
|
|
|
|
112MegaRAID Enterprise 1600 Hardware Guide