DOS ASPI Driver Error Messages

Message

 

Corrective Action

 

LSI Logic ASPI Manager has

The ASPI manager is not loaded. One of the failure

 

NOT been loaded.

codes listed below is displayed next.

 

Controller setup FAILED

Correct the condition that caused the failure. The

 

error code=[0xab]

failure codes are:

 

 

0x40

No MegaRAID adapters found

 

 

0x80

Timed out waiting for interrupt to be posted

 

 

0x81

Timed out waiting for the MegaRAID

 

 

 

Response command.

 

 

0x82

Invalid command completion count.

 

 

0x83

Invalid completion status received.

 

 

0x84

Invalid command ID received.

 

 

0x85

No MegaRAID adapters found or no PCI

 

 

 

BIOS support.

 

 

0x90

Unknown Setup completion error

 

No non-disk devices were

The driver did not find any non-hard drive devices

 

located

during scanning. A SCSI device that is not a hard disk

 

 

drive, such as a tape drive or CD-ROM drive, must be

 

 

attached to this SCSI channel. The SCSI ID must be

 

 

unique for each adapter and cannot be SCSI ID 0. The

 

 

supported SCSI IDs are 1, 2, 3, 4, 5, and 6.

 

'ERROR: VDS support is

The /h option is appended to driver in

 

*INACTIVE* for

CONFIG.SYS or this driver is used with a BIOS that

 

MegaRAID logical drives

is earlier than v1.10, or no logical drives are

 

 

configured.

 

 

 

 

 

112MegaRAID Enterprise 1600 Hardware Guide