AF4000 Valve

If erratic system behavior is observed that cannot be resolved by the methods outlined below, ensure that there is not a transmitter with batteries installed that may be interfering. If a transmitter is packed with batteries installed, its buttons may be depressed sending a constant signal which can interfere with the transmission of desired signals. A transmitter with new batteries can have a range of over 100’ (30.4 m).

Module will not learn trans- mitter

Ensure the REMOTE/OFF switch on the side of the module (Fig. 45) is set to RE- MOTE.

Make sure the batteries in both the transmitter and receiver are installed in the proper direction and are not drained. Individual battery voltage should be no less than 1.4V for AA and AAA batteries, 2.8V for button cells, and 9.0V for 12V batter- ies.

Verify the transmitter indicates a signal is being sent. With thermostat transmit- ters, the LCD display should indicate ON or OFF depending on which button is being pressed. The LED indicator should illuminate on wall transmitters and on/off hand-held transmitters. Buttons should be pressed and held for 1 to 2 seconds to ensure a complete signal is sent.

Make sure the transmitter is within the 20’ (6 m) operational range of the receiver.

Ensure the 4-pin lead-set is securely connected from the battery pack to the control module’s AUX connection. (Fig. 45) If the A/C power adapter is used, make sure the leads from the adapter are securely connected to the POWER terminals on the control module. (Fig. 47)

Press and hold the LEARN button on the module (Fig. 46) for approximately 10 seconds to clear the memory (you should hear a series of beeps from the re- ceiver). Then press and release the learn button (you should hear a single beep from the receiver), immediately press either the ON or OFF button on the transmit- ter (you should hear a series of beeps indicating the transmitter code has been learned).

Figure 45: AF4000

MOD Module Right

Side

Continuous PIlot Off/On Switch

Remote/Off

SwitchAdjustment

Figure 46: AF4000 MOD Module Left Side

 

“I” Pilot

FP1762

“S” Pilot Connection

 

Connection

 

 

 

Learn Button

AUX Connection

FP1763