Majestic Appliances RDV4136 Series Direct Vent Gas Fireplace, Start, Check, No No No No

Models: RDV4136

1 40
Download 40 pages 58.84 Kb
Page 30
Image 30
Troubleshooting - Honeywell VS8421

RDV4136 Series Direct Vent Gas Fireplace

 

Troubleshooting - Honeywell VS8421

 

Remove Window Frame Assembly Before Service Work

START

CHECK

Gas Supply On

YES

Pilot Lights With Piezo Ignitor

YES

Pilot Stays Lit

YES

Pilot Lights Main Burner

YES

SYSTEM OK

NO

NO

NO

NO

Supply Line Hooked Up

Shutoff Valve Open

Lockout Has Engaged. Wait 60 Seconds And Try Again.

For Spark At Electrode While Depressing Piezo

1/8" Gap To Pilot Hood Needed.

All Wiring Connections

Replace Piezo Ignitor

For Air In The Lines

Thermopile Needs A Min. 325m V. Adjust Pilot Flame Height.

All Wiring Connections

Replace Thermopile

Thermocouple Needs A Min. Of 14m V

Valve Is Turned On

Wall Switch Is Not Turned On. Watch For Grounded Wires!

Thermopile Needs A Min. 325m V.

Plugged Burner Orifice

Defective Valve. Turn to Pilot, Me- ter should rear greater than 100m V. If not, replace.

30

10010618

Page 30
Image 30
Majestic Appliances RDV4136 Series Direct Vent Gas Fireplace, Troubleshooting - Honeywell VS8421, Start, Check