RDV4136 Series Direct Vent Gas Fireplace
1/2” Hole,
1/4 Open
Air Shutter
Air Shutter Screw
CO148
Fig. 53 Air shutter setting.
Pilot Orifice Conversion
1.Remove pilot hood by lifting up. (Fig. 54)
2.Remove pilot orifice with Allen wrench. (Fig. 55)
3.Install conversion pilot orifice.
Pilot Hood
Pilot
Bracket
CO133
Fig. 54 Remove pilot hood.
Index Tab | Allen Wrench |
|
Snap Ring
CO134
Fig. 55 Remove pilot orifice.
4.Reinstall pilot hood and be sure to align with index tab.
5.Turn the gas supply valve and gas valve on and test for leaks. Use a 50/50 solution of liquid soap and water to test for leaks at gas fittings and joints. Apply water/soap solution with brush only - do not over ap- ply. NEVER test with an open flame.
6.Follow procedure on rating plate to light the pilot. Check for leaks.
7.Turn main burner on and check for leaks.
8.Reinstall bracket rear log, front grate and logs. Refer to Page 22 for proper log placement.
Fuel Conversion complete.
Table 1 Injector Orifice Size Matrix
Conversion to LP
|
| Burner Orifice |
|
| Input (BTU/hr) | ||
Kit # | Model | Description | Part # | Minimum Rate Screw | Minimum | Maximum | |
10010737 | RDV4136RN | #53 (.0595”) | 54833 |
| n/a | 19,500 | 24,000 |
| RDV4136IN | #53 (.0595”) | 54833 | #54 | 20013177 | 19,500 | 24,000 |
|
| Conversion to Natural Gas |
|
|
| ||
|
| Burner Orifice |
|
| Input (BTU/hr) | ||
Kit # | Model | Description | Part # | Minimum Rate Screw | Minimum | Maximum | |
10010736 | RDV4136RP | #40 (.098”) | 55616 |
| n/a | 15,300 | 24,000 |
| RDV4136IP | #40 (.098”) | 55616 | #33 | 20014169 | 15,300 | 24,000 |
|
|
|
|
|
|
|
|
32 | 10010618 |