EB-1 Electrical Box

The fireplace, when installed, must be elec- trically connected and grounded in accord- ance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code.

For USA installations follow local codes and the national electrical code ANSI/ NFPA No. 70.

It is strongly suggested that the wiring of the EB-1 Electrical Junction Box be carried out by a licensed electrician.

Ensure that the power to the supply line has been disconnected before commenc- ing this procedure.

The EB-1 Electrical junction box has been fitted stand- ard on this model to allow for the easy connection of an optional fan kit.

RDV4136 Series Direct Vent Gas Fireplace

To connect the EB-1 box to the house electrical supply follow the steps below.

1.Unscrew retaining screw from EB-1 base plate (Fig. 8) and remove the EB-1 assembly from the appli- ance.

2.Remove the front cover of the EB box.

3.Remove the plug socket assembly from the EB-1 box.

4.Feed the supply line in through the EB-1 opening in the side of the appliance and then through the back of the EB-1 assembly. (Fig. 8)

5.Connect the black wire of the power supply line to the brass screw (polarized) of the socket assembly.

6.Connect the white wire of the power line to the chrome screw of the socket assembly.

7.Connect the ground wire of the supply line to the green screw of the socket assembly.

8.Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the EB-1 base plate and refit the EB-1 assembly to the unit with the screw removed in step 1.

INSIDE

ElectricalBox Box

 

 

Retaining Screw

FRONT

 

OF UNIT

 

OUTSIDE

 

OF

UNIT

 

FRONT

FP580

Fig. 8 EB-1 receptacle.

10010618

9

Page 9
Image 9
Majestic Appliances RDV4136 installation instructions EB-1 Electrical Box, EB-1 receptacle