Master Lock XR20 manual Zone Monitor, Using the Bypass Zones Function

Models: XR20

1 44
Download 44 pages 37.45 Kb
Page 20
Image 20

Bypass Zones

User Code Level: Master or Standard.

Function: Allows you to bypass a zone prior to arming the system.

Bypassing is usually done when a zone cannot be restored to normal and you want to arm the system. Once bypassed, the system will not respond to any activity on the zone.

A zone can be bypassed only while it is disarmed. Since Fire, Panic, Emergency, and Supervisory zones are always armed, they can never be bypassed.

The Bypass Zones function can also be used to restore a bypassed zone back into the system.

When Bypass Zones is selected, a report of the bypassing can be sent to your central station. This is optional and can be programmed for you at any time.

Using the Bypass Zones Function

1.Access the User Menu.

2.Press the COMMAND key until BYPASS ZONES? displays.

3.Press any one of the Select keys. The keypad displays ZONE: - RST BYPS.

4.To reset a zone, enter the zone number and press the Select key under RST.

5.To Bypass a zone, enter the zone number and press the Select key under BYPS.

Zone Monitor

User Code Level: Master and Standard.

Function: Allows the system to monitor selected disarmed zones (doors, windows, or motion detectors). When a monitored zone is tripped, the keypad sounds a tone and displays the zone name. This is an ideal feature for monitoring door zones to tell when someone comes in or goes out.

You can place any combination of disarmed zones in Zone Monitor but only the most recent zone tripped is displayed. The displayed zone name clears automatically after a short time or when the zone is armed.

Zone Monitor does not function while the system is armed but a zone placed into it will still be monitored when the system is disarmed.

Using Zone Monitor as part of your weekly system test: After using the System Test function, place all perimeter and interior zones in Zone Monitor. Starting at the front door, go around and open and then close each door and window. You should hear the keypad beep each time. The keypad will also display the name of each zone as its device is opened.

Once all protected doors and windows have been tested, walk in front of each motion detector. The keypad should beep to confirm their operation. If at any time during your weekly testing a device does not cause the keypad to beep, call the service department for assistance.

16

XR20 User Menu

Page 20
Image 20
Master Lock XR20 manual Zone Monitor, Using the Bypass Zones Function

FAQ

How do I bypass a zone?

Access the User Menu and use the Bypass Zones function to bypass a zone prior to arming the system. Follow the steps provided in the User Manual.

What is the purpose of the Zone Monitor function?

Zone Monitor allows the system to monitor selected disarmed zones, such as doors, windows, or motion detectors. It alerts you when a monitored zone is tripped, making it ideal for monitoring door zones to tell when someone comes in or goes out.

How do I use Zone Monitor for my weekly system test?

After using the System Test function, place all perimeter and interior zones in Zone Monitor. Test all protected doors, windows, and motion detectors, ensuring the keypad beeps and displays the name of each zone as its device is opened.