Connecting to other Meridian Equipment

To connect to other Meridian 500 Series equipment

Connect one of the COMMS sockets on the rear panel of the multimedia controller to one of the COMMS sockets on another 500 Series unit, using the 500 comms lead provided with the other unit.

The sequence in which you connect the units is not important.

COMMS

COMMS

Then configure the units with the following automatic setup procedure:

Switch all the units to standby.

Press Clear on the remote.

This is the unit that will respond to the remote.

All the other units will be configured

NCon

as non-controllers, and display:

 

Your system is now set up and ready for use.

If, for any reason, the automatic setup does not give the configuration you want, restore the default operation by selecting Type 1 as described in To select a standard setting, page 28.

Note: Do not, under any circumstances, connect any equipment other than Meridian 500, 600, or 200 Series to the socket marked COMMS on the rear of the multimedia controller.

Setting up the multimedia

Each unit will display:

Auto

 

 

 

One unit will then be designated

Con

as the controller, and display:

 

controller

25

Page 30
Image 30
Meridian America 562V.2 manual Connecting to other Meridian Equipment, To connect to other Meridian 500 Series equipment