Appendix 3 – RS232 | 48 |
|
|
Appendix 3 – RS232
The 518 may be operated via its RS232 interface.
Set the communication settings as follows:
∙Baud rate 9600
∙Data bits 8
∙Stop bit 1
∙Parity none
The 518 is operated by sending short command strings on the RS232 interface. Each command is terminated by a <return> (dec. 13). No echo is implemented. Any subsequent <return> on its own repeats the last command.
518 returns useful strings acknowledging the command and giving status information.
Handset Functions
The following commands emulate the MSR remote control keys.
Sources send one of: CD, RD, LP, TV, T1, T2, CR, CB, TX, V1, V2, LD
Numbers send one of: N1, N2, N3, N4, N5, N6, N7, N8, N9, N0, DP (decimal point)
Menus send one of: ML, MR, MP, MM (for w, e, n, s.)
Source send one of: PR (previous), PL (play), NE (next), PS (pause), FB (fast back), ST (stop), FF (fast forward), RC (record), RP (repeat)
Memory: SR (store), CL (clear)
Status: DI (display), SB (standby)
Volume: VP (up), VM (down), MU (mute)
GoTo Functions
There are direct access functions that use
VN## | Goto volume number |
GN±## | Goto gain number |
BP | Goto DSP Bypass |
GA | Goto DSP Gain |
EM | Goto DSP Emphasis |
DE | Goto DSP |
DT# | Goto dither # (0=flat, 1= HP, ....6=ShapeE) |
IN## | Goto input bits ## |
OU##C | Goto output bits ## (Consumer format) |
OU##P | Goto output bits ## (Professional format) |
518 User Guide