Appendix 3 – RS232

48

 

 

Appendix 3 – RS232

The 518 may be operated via its RS232 interface.

Set the communication settings as follows:

Baud rate 9600

Data bits 8

Stop bit 1

Parity none

The 518 is operated by sending short command strings on the RS232 interface. Each command is terminated by a <return> (dec. 13). No echo is implemented. Any subsequent <return> on its own repeats the last command.

518 returns useful strings acknowledging the command and giving status information.

Handset Functions

The following commands emulate the MSR remote control keys.

Sources send one of: CD, RD, LP, TV, T1, T2, CR, CB, TX, V1, V2, LD

Numbers send one of: N1, N2, N3, N4, N5, N6, N7, N8, N9, N0, DP (decimal point)

Menus send one of: ML, MR, MP, MM (for w, e, n, s.)

Source send one of: PR (previous), PL (play), NE (next), PS (pause), FB (fast back), ST (stop), FF (fast forward), RC (record), RP (repeat)

Memory: SR (store), CL (clear)

Status: DI (display), SB (standby)

Volume: VP (up), VM (down), MU (mute)

GoTo Functions

There are direct access functions that use two-character codes that may be followed by additional numbers or parameters.

VN##

Goto volume number

GN±##

Goto gain number

BP

Goto DSP Bypass

GA

Goto DSP Gain

EM

Goto DSP Emphasis

DE

Goto DSP De-emphasis

DT#

Goto dither # (0=flat, 1= HP, ....6=ShapeE)

IN##

Goto input bits ##

OU##C

Goto output bits ## (Consumer format)

OU##P

Goto output bits ## (Professional format)

518 User Guide

Page 48
Image 48
Meridian America Meridian 518 manual Appendix 3 RS232, Handset Functions, GoTo Functions