3.2.3.Multiread

DISACTIVATED *

ACTIVATED

The Multiread function permits the temporary storage of one or more codes in the decoder's memory which will then be transmitted in a single string message.

To operate the Multiread function, the desired group of codes to be first stored must have a Multiread Character as the leading character. This character can be chosen in the Multiread Character Table (see appendix 6.9, page 67; default is SPACE character) after reading code Activated. The transmission will start once a code having no Multiread Character is read.

3.2.4.Modulo 43 Check Character

In the case of high level security applications, a check character can be integrated as the last character in the code and verified before transmission.

NOT VERIFIED *

VERIFIED AND TRANSMITTED

VERIFIED AND NOT TRANSMITTED

!Note:

See page 27 for the calculation algorithm of Code 39 Modulo 43 Check Character.

START OF CONFIGURATION

END OF CONFIGURATION

 

 