Problem solving guide

Problem

Possible cause

Remedy

The door cannot be

For safety reasons the

Option 1

opened during or after

door cannot be

Wait until the temperature has

drying.

opened when the

dropped below 70°C and then

 

internal temperature is

open the door.

 

above 70°C.

Option 2

 

 

 

 

Select the cooling down

 

 

phase*:

 

 

– Turn the DRYING

 

 

programme selector to the

 

 

Finish position.

 

 

– Turn the DRYING

 

 

programme selector imme-

 

 

diately to a programme:

 

 

the Cooling down indicator

 

 

lamp will light up and the

 

 

cooling down phase has

 

 

been selected.

 

 

– At the end of the cooling

 

 

down phase (the Anti-

 

 

crease/Finish light comes

 

 

on), you can open the door.

 

 

* If the drying programme has

 

 

already finished, first start a

 

 

new drying programme for a

 

 

few minutes.

 

 

Option 3

 

 

Activate the programmable

 

 

function "Opening the door at

 

 

high temperatures".

48

Page 48
Image 48
Miele wt945, WT 945 S WPS operating instructions Option, Opened during or after, Drying