Miller Electric 280 NT manual Duty Cycle, TIG Mode Volt-Ampere Curves, Continuous Welding

Models: 280 NT

1 60
Download 60 pages 24.17 Kb
Page 20
Image 20
4-7. Duty Cycle

. A complete Parts List is available at www.MillerWelds.com

4-7. Duty Cycle

100% Duty Cycle at 280 Amperes DC/CC

Continuous Welding

Duty cycle is the percentage of 10 minutes that unit can weld at rated load without overheating.

NOTICE − Exceeding duty cycle can damage unit and void warranty.

325Continuous Welding

MIG/FCAW

300

WELD AMPERES

275

STICK

250

225

200

175

150

0

10

20

30

40

50

60

70

80

90

100

% DUTY CYCLE

Ref. 207 925

4-8. TIG Mode Volt-Ampere Curves

DC VOLTS

50

 

45

 

40

3600RPM Max

35

3000RPM Max

30

 

25

20

15 Min

10

5

0

0

100

200

300

400

 

 

DC AMPERES

 

 

The volt-ampere curves show the minimum and maximum voltage and amperage output capabilities of the welding generator. Curves of other settings fall between the curves shown.