Miller Electric 280 NT Generator Power Curve, Weld Position Flat, Horizontal, Vertical, Overhead

Models: 280 NT

1 60
Download 60 pages 24.17 Kb
Page 19
Image 19
4-6. Generator Power Curve

. A complete Parts List is available at www.MillerWelds.com

4-6. Generator Power Curve

The ac generator power curve shows the generator power avail- able in amperes at the receptacles.

 

300

 

 

 

 

 

 

 

250

 

 

 

 

 

 

AC VOLTS

200

 

 

 

 

 

 

150

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

0

5

10

15

20

25

30

 

 

 

 

AC AMPERES

 

 

 

222 553

Notes

WELD POSITION: FLAT

HORIZONTAL

VERTICAL

 

OVERHEAD

WELD JOINT

BUTT

BUTT

 

 

BUTT

TYPES

1G

BUTT

 

4G

2G

 

 

 

3G

 

 

 

 

 

T−JOINT

T−JOINT

 

GROOVE

 

 

2F

 

 

 

4F

 

FILLET

T−JOINT

 

 

T−JOINT

 

 

 

3F

 

Ref. AWS/ANSI D1.1

1F

 

 

Ref. 804 248-A

 

 

 

OM-4430 Page 15

Page 19