5-4. Display Board PC4 Meter Check

Check points are provided on display board PC4 for checking power supply and input command to meters.

To make checks at display board, open front access door.

REAR VIEW OF DISPLAY BOARD PC4

1Display Board PC4

2Meter

CB1 protects the wire feed motor from overload. If CB1 opens, the wire feed mo-

Input Command For

Wire Speed IPM Meter

0.8V = 800 IPM

tor stops. Check for jammed wire, binding drive gear, or misaligned drive rolls. Cor- rect problem.

Allow cooling period and manually reset breaker.

Input Command For

Volts Meter –0.5V = 50V

Power Supply For Wire

Power Supply For

Speed IPM Meter 5VDC

Volts Meter And

 

Ammeter 5VDC

1

Receptacle RC20

2

Receptacle RC24

Ref. ST-117 838-B / Ref. ST-119 647-C

OM-884 Page 24

Page 28
Image 28
Miller Electric A.B.B. Robot Interface Gas Control Hub And Spindle Display Board PC4 Meter Check, Speed IPM Meter 5VDC