5-6. Use Of Indicator Lights For Troubleshooting
| On |
|
|
|
|
| Gas Indicator Light |
|
| Off | ||||
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| |||||
Gas flows: | Gas does not flow: | Gas flows: | Gas does not flow: | |||||||||||
System normal (on.) | Check gas valve operation. | Check gas valve operation | System normal (off). | |||||||||||
|
|
|
|
|
|
|
| and gas line for leaks. |
|
|
| |||
|
|
|
|
|
|
|
| Check interface board PC3. |
|
|
| |||
| On |
|
|
|
| Contactor Indicator Light |
|
| Off | |||||
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
| ||||||||||
Contactor closed: | Contactor open: | Contactor closed: | Contactor open: | |||||||||||
System normal (on). | Check interconnecting cords. | Check display board PC4. | System normal (off). | |||||||||||
|
|
| Check interface board PC3. |
|
|
|
|
|
|
| ||||
| On |
|
|
|
| Wire Feed Indicator Light |
|
| Off | |||||
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wire feeds: | Wire does not feed: |
System normal (on). | Check circuit breaker CB1. |
| Check relay CR1. |
| Check interface board PC3. |
Wire feeds: | Wire does not feed: |
Check input signal from | System normal (off). |
robot to motor board PC2. |
|
Signal should be |
|
between pins K and B |
|
(common) at RC5. |
|
Check motor board PC2. |
|
On Current Indicator Light Off
Arc started: | No arc: | Arc started: | No arc: |
System normal (on). | Replace reed relay. | Replace reed relay. | System normal (off). |
On Arc Failure Indicator Light Off
No arc: | Arc started: | No arc: | Arc started: |
Check weld | Check signal from robot. | Normal during idling. | Normal while welding. |
parameters. | Signal should be 24 vdc |
|
|
| between terminals 1 TL |
|
|
| and 1 TM. |
|
|
| Check display board PC4. |
|
|