3-4. Indicator Lights

1

2

3

4

5

1 Gas Indicator Light

Gas sight turns on when the gas valve is energized to indicate shielding gas flow.

2 Contactor Indicator Light

Contactor light turns on when the welding power source contactor is energized to indicate that weld output is available.

3 Wire Feed Indicator Light

WIRE FEED light turns on when the wire drive motor is energized to in- dicate that wire is feeding.

4 Current Indicator Light

Current light turns on when the current detect relay is energized to indicate that an arc is established.

5 Arc Failure Indicator Light

Arc Failure light turns on only when properly connected according to in- structions in Section 2-10, and there is an arc outage while welding.