5-4. Stick Start Procedure − Scratch Start Technique

With Stick selected, start arc as follows:

1 Electrode

2 Workpiece 3 Arc

Drag electrode across workpiece like strik-

1ing a match; lift electrode slightly after touch- ing work. If arc goes out electrode was lifted to high. If electrode sticks to workpiece, use a quick twist to free it.

Y For models with stock number 907 220, normal open-circuit voltage (80

2volts) is present before electrode touches workpiece.

For models with stock numbers 907 036 and

3907 037, normal open-circuit voltage is not present before electrode touches work- piece; only a low sensing voltage is present between electrode and workpiece.

5-5. Amperage Control

CE Model

1 A (Amperage Control)

1

 

Rotate knob clockwise to increase

1

amperage (Min-200 amps).

 

Min

Min

5-6. DIG Control

 

CE Model

 

1 DIG Control

1

1

 

Control increases SMAW short-cir-

 

 

 

cuit amperage at low arc voltage.

 

 

 

This allows the operator to use a

 

 

 

very short arc length without stick-

 

 

 

ing the electrode.

 

 

 

Set control at 0 for normal welding

 

 

 

amperage. Turn clockwise to in-

 

 

 

crease short-circuit amperage.