5-10. Electrical Service Guide

 

 

 

 

60 Hz

 

Single

 

Phase

 

 

Input Voltage

230

 

 

Input Amperes At Rated Output

20

 

 

Max Recommended Standard Fuse Rating In Amperes

 

Circuit Breaker 1, Time-Delay 2

25

Normal Operating 3

30

Min Input Conductor Size In AWG 4

14

Max Recommended Input Conductor Length In Feet (Meters)

67

(20)

 

 

 

Min Grounding Conductor Size In AWG 4

14

Reference: 2005 National Electrical Code (NEC) (including article 630)

 

1Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.

2“Time-Delay” fuses are UL class “RK5” .

3“Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).

4Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table 310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.

Failure to follow these fuse and circuit breaker recommendations could create an electric shock or fire hazard. These recommendations are for a dedicated branch circuit that applies to the rated output and duty cycle of the welding power source.

5-11. Installing Wire Spool And Adjusting Hub Tension

 

 

1

Adapter

Installing 4 in. (102 mm) Wire Spool

 

 

2

Retaining Ring

When a slight force is needed to turn spool, tension is set.

Installing 8 in. (203 mm) Wire Spool

1

2

Tools Needed:

1/2 in

803 012 / 803 013 -B / Ref. 802 444-C

OM-228 042 Page 22

Page 26
Image 26
Miller Electric Renegade 180 manual Electrical Service Guide, Installing Wire Spool And Adjusting Hub Tension, Adapter