. Complete Parts List available at www. MillerWelds.com

6-2. Description Of Controls (See Section 6-1)

1 Engine Switch

Use switch to control ignition circuit.

For Recoil Start: Turn switch to On position when starting engine. Turn switch to Off posi- tion to stop engine. Engine cannot be started with switch in the Off position.

For Electric Start: Turn switch to Start position when starting engine. Switch returns to Run position when engine starts. Turn switch to Off position to stop engine.

Engine stops if oil level is too low. Engine can- not be restarted until sufficient oil is added.

2 Low Oil Pressure Light

Light goes on and engine stops if engine oil level is too low.

Engine cannot be restarted until sufficient oil is added.

NOTICE − Stop engine and add oil if light goes on (see Section 5-3).

3Starter Handle

4Choke Control

Use control to change engine air/fuel mix. Move control to far right if starting a cold en-

gine. Move control to far left if starting a warm engine.

To Start:

DOpen fuel valve (see Section 5-3).

DSet choke.

DFor Recoil Start: Turn Engine switch to On and pull starter handle.

DFor Electric Start: Turn Engine switch to Start. When engine starts, allow switch to return to Run position.

DOpen choke as engine warms.

NOTICE − If the engine does not start, let engine come to a complete stop before at- tempting restart.

To Stop:

DTurn Engine switch to Off.

.Always close fuel valve after stopping unit. Moving unit with fuel valve open may cause carburetor flooding and make starting difficult.

5 Wire Speed Control

Turn control clockwise to increase wire feed speed. (see weld parameter chart in welding power source or Section 6-3).

6 Voltage Control

Turn control clockwise to increase voltage (see weld parameter chart in welding power source or Section 6-3).

7Gun Trigger Receptacle

8Wall/Generator Switch

Use switch to select source of power for weld- ing power source.

Place switch in Generator position for welding power source to run on generator input power.

Place switch in Wall position for the welding power source to run on utility power. Place switch in Off position before connecting to util- ity power.

.With switch in the Wall position and the

generator not running, the auxiliary power receptacles do not work.

9 Over Temperature Light

Light flashes when unit has overheated and weld output is not available. Allow fan to run to cool unit. When light goes out, unit is ready for service.

OM-228 042 Page 27