SECTION 5 − INSTALLATION

5-1. Installing Welding Generator

Movement

. Shown with standard running gear and optional cylinder rack.

Airflow Clearance

18 in

18 in

(460 mm)

(460 mm)

18 in

(460 mm)

18 in

18 in

(460 mm)

(460 mm)

Location

Always securely fasten welding generator onto transport vehicle or trailer and comply with all DOT and other applicable codes.

2

GND/PE3

Do not install unit where air flow is restricted or engine may overheat.

Always ground generator frame to vehicle frame to pre- vent electric shock and static electricity hazards.

1Metal Vehicle Frame

2Equipment Grounding Terminal

3Grounding Cable

Bed liners, shipping skids, and some running gear insu- late the welding generator from the vehicle frame. Al- ways connect a ground wire from the generator equip- ment grounding terminal to bare metal on the vehicle frame as shown.

Use #10 AWG or larger insulated

1copper wire to make metal-to-metal grounding connection.

If unit does not have GFCI receptacles, use GFCI- protected extension cord.

Ref. install 11/02 − Ref. 800 652 / 804 476-C / S-0854