8355 N/B MAINTENANCE

7.2 Error Codes

Following is a list of error codes in sequent display on the PIO debug board.

Code

POST Routine Description

 

 

30h

Special init of keyboard ctlr

 

 

31h

Test if keyboard Present

 

 

32h

Test keyboard Interrupt

 

 

33h

Test keyboard command byte

 

 

34h

Test, blank and count all RAM

 

 

35h

Protected mode entered safely(2)

 

 

36h

RAM test complete

 

 

37h

Protected mode exit successful

 

 

38h

Update output port

 

 

39h

Setup cache controller

 

 

3Ah

Test if 18.2Hz periodic working

 

 

3Bh

Test for RTC ticking

 

 

3Ch

Initialize the hardware vectors

 

 

3Dh

Search and init the mouse

 

 

3Eh

Update NUMLOCK status

 

 

3Fh

Special init of COMM and LPT ports

 

 

Code

POST Routine Description

 

 

40h

Configure the COMM and LPT ports

 

 

41h

Initialize the floppies

 

 

42h

Initialize the hard disk

 

 

43h

Initialize option ROMs

 

 

44h

OEM’s init of power management

 

 

45h

Update NUMLOCK status

 

 

46h

Test for coprocessor installed

 

 

47h

OEM functions before boot

 

 

48h

Dispatch to operate system boot

 

 

49h

Jump into bootstrap code

 

 

50h

ACPI init

 

 

51h

PM init & Geyserville CPU init

 

 

52h

USB HC init

 

 

118