8355 N/B MAINTENANCE

8.4 AGP Controller Failure LCD No Display

Symptom:

There is no display on LCD although power-on-self-test is passed.

AGP Controller Failure

1.Confirm LCD panel or monitor is good and check the cable are connected properly.

2.Try another known good monitor or LCD module.

Board-level

Troubleshooting

Check if MB:U506,U16, J2, J3, Yes

Charge BD: J2,J3 are cold colder?

No

Re-soldering.

Display

Yes

Replace faulty

 

 

OK?

 

 

LCD or monitor.

 

 

No

 

 

 

 

 

 

 

 

Remove all the I/O device & cable from motherboard except LCD panel or extended monitor.

Replace

Motherboard

One of the following parts on the mother-board may be defective, use an oscilloscope to check the following signal or replace the parts one at a time and test after each replacement.

Parts:

 

Signals:

 

U506

X3

TXCLK+

BLADJ

 

 

 

Yes

Connect the I/O device & cable

Display

to the M/B one at a time to find

 

OK?

 

out which part is causing the

 

 

 

No

 

problem.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U511

F501

TXCLK-

ENAVDD

U9

Q518

TX2CLK+

 

U16

Q503

TX2CLK-

 

J2

Q501

TXOUT[0:3]+

 

J3

R503

TXOUT[0:3]-

 

R94

R504

TX2OUT[0:3]+

 

C211

L46

TX2OUT[0:3]-

 

R137

L39

PANEL_ID[0:3]

 

R141

L42

ENABL_VGA

 

R139

D503

+PANEL_VDD

 