PARAMETERS
22
Func-
tion
Parameter
Number Name Setting Range
Minimum
Settin
g
Increments
Factory Setting
Refer To
Page:
<Note9>
200 Programmed operation minute/second
selection 0 to 3 1 0 131
201 Program set 1
1 to 10
0 to 2: Rotation direction
0 to 400, 9999:Frequency
0 to 99.59: Time
1
0.1Hz
Minute or second
0
9999
0
131
211 Program set 2
11 to 20
0 to 2: Rotation direction
0 to 400, 9999:Frequency
0 to 99.59: Time
1
0.1Hz
Minute or second
0
9999
0
131
221 Program set 3
21 to 30
0 to 2: Rotation direction
0 to 400, 9999:Frequency
0 to 99.59: Time
1
0.1Hz
Minute or second
0
9999
0
131
Programmed operation
231 Timer setting 0 to 99.59  0 131
232 Multi-speed setting (speed 8) 0 to 400Hz, 9999 0.01Hz 9999 135
233 Multi-speed setting (speed 9) 0 to 400Hz, 9999 0.01Hz 9999 135
234 Multi-speed setting (speed 10) 0 to 400Hz, 9999 0.01Hz 9999 135
235 Multi-speed setting (speed 11) 0 to 400Hz, 9999 0.01Hz 9999 135
236 Multi-speed setting (speed 12) 0 to 400Hz, 9999 0.01Hz 9999 135
237 Multi-speed setting (speed 13) 0 to 400Hz, 9999 0.01Hz 9999 135
238 Multi-speed setting (speed 14) 0 to 400Hz, 9999 0.01Hz 9999 135
Multi-speed operation
239 Multi-speed setting (speed 15) 0 to 400Hz, 9999 0.01Hz 9999 135
240 Soft-PWM setting 0, 1 1 1 135
Sub functions
244 Cooling fan operation selection 0, 1 1 0 135
Stop selection
function
250 Stop selection 0 to 100 sec, 9999 0.1 sec 9999 135
Sub
functions
251 Start holding time 0 to 10 sec, 9999 0.1 sec 9999 136
261 Power failure stop selection 0, 1 1 0 137
262 Subtracted frequency at deceleration
start 0 to 20Hz 0.01Hz 3Hz 137
263 Subtraction starting frequency 0 to 120Hz, 9999 0.01Hz 60Hz<50Hz> 137
264 Power-failure deceleration time 1 0 to 3600/
0 to 360 sec
0.1 sec/
0.01 sec 5 sec 137
265 Power-failure deceleration time 2 0 to 3600/
0 to 360 sec, 9999
0.1 sec/
0.01 sec 9999 137
Power failure stop function
266 Power-failure deceleration time switch-
over frequency 0 to 400Hz 0.01Hz 60Hz 137
Selection
function
270 Stop-on-contact/load torque high-speed
frequency control selection 0, 1, 2, 3 1 0 139
271 High-speed setting maximum current 0 to 200% 0.1% 50% 140
272 Mid-speed setting minimum current 0 to 200% 0.1% 100% 140
273 Current averaging range 0 to 400Hz, 9999 0.01Hz 9999 140
High-speed
frequency
control
274 Current averaging filter constant 1 to 4000 1 16 140
275 Stop-on-contact exciting current low-
speed multiplying factor (Note 5) 0 to 1000%, 9999 1% 9999 143
Stop on
contact
276 Stop-on-contact PWM carrier frequency
(Note 5) 0, 1, 2, 9999 1 9999 143