PROTECTIVE FUNCTIONS

 

 

 

 

 

 

Operation

Parameter

 

 

 

Panel

 

 

 

Unit

Name

Description

 

Display

 

(FR-PU04)

 

 

 

(FR-DU04)

 

 

 

 

 

 

 

 

 

 

When the operation panel power (P5S of the PU connector) is shorted,

 

 

 

Operation panel power short

this function shuts off the power output. At this time, the operation panel

 

E.CTE



(parameter unit) cannot be used and RS-485 communication from the PU

 

circuit

 

 

 

connector cannot be made. To reset, enter the RES signal or switch

 

 

 

 

 

 

 

 

power off, then on again.

 

 

 

 

 

 

 

 

 

Inverters of 7.5K or less contains a brake resistor. When the regenerative

 

 

 

 

brake duty from the motor has reached 85% of the specified value, pre-

 

 

 

Brake resistor overheat

alarm (RB indication) occurs. If the specified value is exceeded, the brake

 





circuit operation is stopped temporarily to protect the brake resistor from

 

protection

 

 

 

overheating. (If the brake is operated in this state, regenerative

 

 

 

 

 

 

 

 

overvoltage shut-off will occur.) When the brake resistor has cooled, the

 

 

 

 

brake operation is resumed.

 

 

 

 

 

 

E.MB1 to



Brake sequence error

This function stops the inverter output if a sequence error occurs during

 

MB7

the use of the brake sequence function (Pr. 278 to Pr. 285).

 

 

 

 

 

 

 

 

 

E.14

E.14

DC fuse blown

The inverter output will stop if the DC fuse blows.

 

 

 

 

 

 

 

 

 

Brake unit cooling fin overheat, control board ambient temperature error,

 

E.15

E.15

Main circuit error

output overcurrent, cooling fan power supply error, capacitor overcurrent,

 

cooling fin overheat, gate power supply error.

 

 

 

 

 

 

 

 

Refer to the next page (page 27) for details.

 

Note: 1. If Pr. 195 (A, B, C terminal function selection) is as set in the factory.

2.The terminals used must be allocated using Pr. 190 to Pr. 195.

3.External thermal relay operation is only activated when "OH" is set in any of Pr. 180 to Pr. 186 (input terminal function selection).

4.Indicates that the stall prevention operation level has been set to 150% (factory setting). If this value is changed, stall prevention is operated at the new value.

5.Resetting method

When the protective function is activated and the inverter stops its output (the motor is coasted to a stop), the inverter is kept stopped. Unless reset, the inverter cannot restart. To reset the inverter, use any of the following methods: switch power off once, then on again; short reset terminal RES- SD for more than 0.1 seconds, then open; press the [RESET] key of the parameter unit (use the help function of the parameter unit). If RES-SD is kept shorted, the operation panel will show "Err." or the parameter unit will show that the inverter is being reset.

26

Page 37
Image 37
Mitsubishi Electronics FR-A500L instruction manual Cte, MB7