PARAMETERS

Func-

Parameter

 

 

Minimum

Factory Setting

Refer To

Name

Setting Range

Setting

Page:

tion

Number

 

 

Increments

 

<Note9>

 

 

 

 

 

flexiblepoint-5V/F characteristics

107

V/F4 (fourth frequency voltage)

0 to 1000V

0.1V

0

98

(Note 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

108

V/F5 (fifth frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

98

 

 

 

 

 

 

 

 

109

V/F5 (fifth frequency voltage)

0 to 1000V

0.1V

0

98

 

(Note 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110

Third acceleration/deceleration time

0 to 3600 sec/

0.1 sec/

9999

99

 

0 to 360 sec, 9999

0.01 sec

 

 

 

 

 

functions

111

Third deceleration time

0 to 3600 sec/

0.1 sec/

9999

99

0 to 360 sec, 9999

0.01 sec

 

 

 

 

 

 

 

112

Third torque boost (Note 1)

0 to 30.0%, 9999

0.1%

9999

99

Third

113

Third V/F (base frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

99

*114

Third stall prevention operation current

0 to 150%

0.1%

150%

99

 

115

Third stall prevention operation frequency

0 to 400Hz

0.01Hz

0

99

 

116

Third output frequency detection

0 to 400Hz, 9999

0.01Hz

9999

99

functions

117

Station number

0 to 31

1

0

99

 

 

10, 11 (data length 7)

 

 

 

 

118

Communication speed

48, 96, 192

1

192

99

 

119

Stop bit length/data length

0, 1 (data length 8)

1

1

99

 

 

Communication

 

 

 

 

 

 

120

Parity check presence/absence

0, 1, 2

1

2

99

 

 

121

Number of communication retries

0 to 10, 9999

1

1

99

 

122

Communication check time interval

0, 0.1 to 999.8 sec,

0.1

0<9999>

99

 

9999

 

 

 

 

 

 

 

123

Waiting time setting

0 to 150ms, 9999

10ms

9999

99

 

124

CR, LF presence/absence selection

0,1,2

1

1

99

 

128

PID action selection

10, 11, 20, 21

1

10

109

control

129

PID proportional band

0.1 to 1000%, 9999

0.1%

100%

109

131

Upper limit

0 to 100%, 9999

0.1%

9999

109

 

130

PID integral time

0.1 to 3600 sec, 9999

0.1 sec

1 sec

109

PID

 

 

 

 

 

 

132

Lower limit

0 to 100%, 9999

0.1%

9999

109

 

 

133

PID action set point for PU operation

0 to 100%

0.01%

0%

109

 

134

PID differential time

0.01 to 10.00 sec, 9999

0.01 sec

9999

109

Commercialpower supply- inverterswitch-over

 

Commercial power supply-inverter

 

 

 

 

135

switch-over sequence output terminal

0, 1, 2

1

0

116

 

selection

 

 

 

 

136

MC switch-over interlock time

0 to 100.0 sec

0.1 sec

1.0 sec

116

 

supply switch-over frequency

 

 

 

 

 

137

Start waiting time

0 to 100.0 sec

0.1 sec

0.5 sec

116

 

138

Commercial power supply-inverter

0, 1

1

0

116

 

switch-over selection at alarm occurrence

 

 

 

 

 

 

 

139

Automatic inverter-commercial power

0 to 60.00Hz, 9999

0.01Hz

9999

116

 

 

 

 

 

 

 

 

 

 

140

Backlash acceleration stopping

0 to 400Hz

0.01Hz

1.00Hz

119

 

frequency (Note 7)

 

 

 

 

 

 

Backlash

141

Backlash acceleration stopping time

0 to 360 sec

0.1 sec

0.5 sec

119

(Note 7)

 

 

 

 

 

 

 

 

142

Backlash deceleration stopping

0 to 400Hz

0.01Hz

1.00Hz

119

 

frequency (Note 7)

 

 

 

 

 

 

 

143

Backlash deceleration stopping time

0 to 360 sec

0.1 sec

0.5 sec

119

 

(Note 7)

 

 

 

 

 

 

Display

144

Speed setting switch-over

0, 2, 4, 6, 8, 10, 102,

1

4

119

 

 

104, 106, 108, 110

 

 

 

 

 

 

 

 

 

 

 

 

 

Additional functions

*149

Stall prevention level at 10V input

0 to 150%

0.1%

150%

58

 

*148

Stall prevention level at 0V input

0 to 150%

0.1%

120%

58

 

 

 

 

 

 

 

20

Page 30
Image 30
Mitsubishi Electronics FR-A500L instruction manual F4 fourth frequency voltage