OC194-35
SW1-6) Switch for set temperature adjustment in heating mode
This is not available for series PL.
SW1-7) Switch for fan speed during thermostat OFF in heating mode
This is not available for series PL.
SW1-8) Switch for fan motor operation in heating mode
This is not available for series PL.
SW1-9) Switch for outdoor unit abnormality detection
OFF :When abnormality occurs, it is detected.
ON : Even if abnormality occurs, it is not detected.
SW1-10) Switch for AUTO RESTART FUNCTION
OFF :This function does not work.
ON : This function works.
(2) SW2 (Address selector)
Use SW2 to set unit-address for group control.
(3) SW3 (Emergency operation switch)
(4) SW5 (Model selector)
SW5-1) OFF :For models without automatic swing mechanism
ON : For models with automatic swing mechanism
SW5-2) OFF :For models with heating mode and cooling mode
ON : For models with only cooling mode including PL
SW5-3) Not yet used
SW5-4) OFF :LOSSNAY on air intake
ON : LOSSNAY air intake
(5) SW6 (Model selector)
SW6 is set on site for twin/triple control.This switch is not available for series PL
4 INDOOR FAN CONTROL
Indoor fan relay output.
(a) During fan ON
The indoor fan relay turns ON.One second later, the phase control will start.
(b) During fan OFF
The phase control turns OFF.One second later, the indoor fan relay will turn OFF.
4 3 2 1
OFF
ON
Normal operation(initial setting) For emergency cooling
654321
OFF
ON
4 3
OFF
ON
2 1
4 3
OFF
ON
2 1
4 3 2 1
OFF
ON