HDV Series Direct Vent Gas Fireplace | Venting installation |
installation planning
There are two basic types of
•Horizontal Termination
•Vertical Termination
It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness.
WARNING
Never run the vent pipe down. This may cause excessive temperatures which could cause a fire.
for horizontal termination
Select the amount of vertical rise desired. All horizontal run of venting must have 1/4" rise for every 12" of run towards the termination below 7Z\x feet of vertical rise. With 7Z\x feet or more vertical rise off top of fireplace, the horizontal run may be level. NEVER run vent piping down.
You may use up to three 90° elbows in this vent configuration. Refer to Horizontal Termination Configurations on Pages 15 and 16.
For vertical termination
Measure the distance from the fireplace floor to the ceiling. Add the ceiling thickness, the vertical rise in an attic or second story, and allow for sufficient vent height above the roof line.
NOTE: You may use two 45° elbows in place of a 90° elbow. You must follow rise to run ratios when using 45° elbows. The appliance is approved for use with three 90° elbows maximum or a combina- tion of 90° and 45° elbows up to a maximum of 270°.
For
You may use a chase with a vent termination with exposed pipe on the exterior of the house. Refer to Installing Vent System in a Chase below. If pipe is enclosed in chase, it is not exposed.
It is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust. Certain limitations apply to vent configurations and must be strictly followed.
Installing a vent system in an outside chase
A chase is a vertical boxlike structure built to enclose venting that runs along the outside of a build- ing. A chase is required for such venting.
NOTICE
When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially important in cold climates. Insulation should be considered a combustible material. Maintain proper clearances to all combustible materials.
NOTICE
Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for the requirements of local building codes. You must follow all local building codes.
14 | 56D3048 |