pRE-INSTALLATION INFORMATION

HDV Series Direct Vent Gas Fireplace

pRE-INSTALLATION INFORMATION

Fireplace Location

Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspections.

The following factors should be taken into consideration:

Clearance to side-wall, ceiling, woodwork, and windows. Minimum clearances to com- bustibles must be maintained.

This fireplace may be installed along a wall, across a corner, or use an exterior chase. Refer to Figure 3 for suggested locations.

Location should be out of high traffic areas and away from furniture and draperies due to heat from appliance.

Never obstruct the front opening of the fireplace.

Do not install in the vicinity where gasoline or other flammable liquids may be stored.

Vent pipe routing. Refer to the Venting section found in this manual for allowable venting configurations.

These units can be installed in a bedroom. See National Fuel Gas Code ANSI Z233.1/ NFPA 54 — (current edition), the Uniform Mechanical Code — (current edition), and Local Building Codes for specific installation requirements.

E

A

B

Y

 

 

 

 

C

X

 

 

Y

D

 

 

B

 

 

 

F

 

Figure 3 -

Locating Gas Fireplace

AFlat on Wall B Cross Corner C Island**

D Room Divider*

E Flat on Wall Corner* F Chase Installation Y 4" Minimum

**Island (C) and room divider (D) installation is possible as long as the horizontal portion of vent system (X) does not exceed 20'. Refer to Installing Horizontal Termination Configuration on Page 13.

*When you install your fireplace in (D) room divider or (E) flat on wall corner positions (Y), a minimum of 6" clearance must be maintained from perpendicular wall and front of fireplace.

56D3048