HDV Series Direct Vent Gas Fireplace | OPTIONAL FAN BLOWER SYSTEM |
Optional Fan/BlOwer System
(BLOTBLDVSC) Installation Instructions Wiring
1.Before installing the blower, wire the receptacle into an electri- cal circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing codes.
2.Remove the external junction box cover by removing the screw from the left side of the outside firebox wall. Junction box was installed at the factory.
120V AC
60Hz
Factory Supplied
Not Supplied
Junction Box
Figure 52 -
Junction Box Wiring Diagram
3.The junction box cover has a factory installed “romex” style
strain relief connector. After connecting the wires, route the wire leads through this con- nector. Refer to the wiring diagram in Figure 52.
| To Junction Box |
|
|
| In Fireplace |
|
|
Dual |
|
| Optional |
|
| AC Box | |
Blowers | Optional | { | |
(300 W | Light | WHITE | |
Max) | WHITE |
| BLACK |
| BLACK |
| BLACK |
| Optional | { WHITE | |
Dual | AUX | ||
|
| GREEN | |
Blowers |
|
| Connector |
(300 W |
|
| |
|
| Pin To Control Box | |
Max) | Figure 53 - |
| |
|
| ||
|
|
| |
| Blower Wiring Diagram | ||
|
|
| Control Box |
|
|
| FP2103 |
WARNING
Electrical Grounding Instructions: This appliance is equipped with a
WARNING
Electrical connections should only be performed by a qualified licensed electrician. Main power supply must be turned off before connecting the fan to the main electrical power supply or performing service.
36 | 56D3048 |