fireplace installation | HDV Series Direct Vent Gas Fireplace |
check gas type
Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fire- place. See dealer where you purchased the fireplace for proper fireplace according to your gas type.
Install gas piping to fireplace location
WARNING
A qualified installer or service person must connect appliance to gas supply. Follow all local codes.
CAUTION
For propane/LP units, never connect fireplace directly to the propane/LP supply. This burner system requires an external regulator (not supplied). Install the external regulator between the burner system and propane/LP supply.
installation items needed
Before installing fireplace and burner system, make sure you have the items listed below.
• | External regulator (supplied by installer) | • Sealant (resistant to propane/LP gas) | |
• | Tee joint | • | Test gauge connection* |
• | Piping (check local codes) | • | Sediment trap (optional but recommended) |
•Pipe wrench
•approved flexible gas line with gas connector (if allowed by local codes — not provided)
*A CSA
For propane/LP connections only, the installer must supply an external regulator. The external regula- tor will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 41. Pointing the vent down protects it from freezing rain or sleet.
| 100 gal. (min) | |
External | Propane/LP | |
Supply Tank | ||
Regulator | ||
|
Vent Pointing
Down
FP1977
Figure 41 -
External Regulator with Vent Pointing Down (Propane/LP Only)
|
| Use only new black iron or steel pipe. |
|
| Internally tinned copper or copper tubing |
| CAUTION | can be used per National Fuel Code, Section |
| minimum inlet pressure (listed on data | |
|
| 2.6.3, providing gas meets hydrogen sulfide |
|
| limits, and where permitted by local codes. |
|
| Gas piping system must be sized to provide |
|
| plate) at the maximum flow rate (BTU/hr). |
|
| Undue pressure loss will occur if the pipe |
|
| is too small. |
|
|
|
| WARNING | External regulators may be necessary for |
| natural gas. One- or | |
|
| |
|
| will damage this appliance and may cause |
|
| fire hazard. |
|
|
|
When using copper or flex connectors use only fittings approved for gas connections. The gas control inlet is 3/8" NPT.
56D3048 | 27 |