Monessen Hearth HDV500NV/PV fireplace installation, check gas type, installation items needed

Models: HDV500NV/PV

1 64
Download 64 pages 30.46 Kb
Page 27
Image 27
fireplace installation

fireplace installation

HDV Series Direct Vent Gas Fireplace

check gas type

Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fire- place. See dealer where you purchased the fireplace for proper fireplace according to your gas type.

Install gas piping to fireplace location

WARNING

A qualified installer or service person must connect appliance to gas supply. Follow all local codes.

CAUTION

For propane/LP units, never connect fireplace directly to the propane/LP supply. This burner system requires an external regulator (not supplied). Install the external regulator between the burner system and propane/LP supply.

installation items needed

Before installing fireplace and burner system, make sure you have the items listed below.

External regulator (supplied by installer)

Sealant (resistant to propane/LP gas)

Tee joint

Test gauge connection*

Piping (check local codes)

Sediment trap (optional but recommended)

Pipe wrench

approved flexible gas line with gas connector (if allowed by local codes — not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your dealer.

For propane/LP connections only, the installer must supply an external regulator. The external regula- tor will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 41. Pointing the vent down protects it from freezing rain or sleet.

 

100 gal. (min)

External

Propane/LP

Supply Tank

Regulator

 

Vent Pointing

Down

FP1977

Figure 41 -

External Regulator with Vent Pointing Down (Propane/LP Only)

 

 

Use only new black iron or steel pipe.

 

 

Internally tinned copper or copper tubing

 

CAUTION

can be used per National Fuel Code, Section

 

minimum inlet pressure (listed on data

 

 

2.6.3, providing gas meets hydrogen sulfide

 

 

limits, and where permitted by local codes.

 

 

Gas piping system must be sized to provide

 

 

plate) at the maximum flow rate (BTU/hr).

 

 

Undue pressure loss will occur if the pipe

 

 

is too small.

 

 

 

 

WARNING

External regulators may be necessary for

 

natural gas. One- or two-pound systems

 

 

 

 

will damage this appliance and may cause

 

 

fire hazard.

 

 

 

When using copper or flex connectors use only fittings approved for gas connections. The gas control inlet is 3/8" NPT.

56D3048

27

Page 27
Image 27
Monessen Hearth HDV500NV/PV fireplace installation, check gas type, Install gas piping to fireplace location, is too small