HDV Series Direct Vent Gas Fireplace | OPERATING INSTRUCTIONS - Millivolt |
Lighting pilot for the first time - millivolt
approved leak testing method
You may check for gas leaks with the following methods only:
•Soap and water solution
•An approved leak testing spray
WARNING
If using a soap and water solution to test for leaks, DO NOT spray solution onto control body.
• Electronic sniffer
DANGER | Never check for gas leak |
| |
| with open flame! |
|
|
Check for gas leaks in each of the following locations:
NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.
• | Pipe from the gas supply line connection to the gas valve | ||
• | Burner connections | • Field made joints / gas shutoff valve | |
• | Pilot | • | Factory made joints |
• | Each joint or connection | • | All joints on valve and control body |
Lighting pilot - millivolt
1.Depress and turn knob counterclockwise to pilot position.
2.Depressfullyandholdpilotgasknob.Depresspiezo ignitor as many times as needed to ignite the pilot. Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
| O |
T | N |
| |
O |
|
L |
|
I |
|
P |
|
| F |
| F |
| O |
PILOT |
Figure 45 - Pilot Position