Monessen Hearth HDV500NV/PV manual Lighting pilot for the first time - millivolt, Pilot

Models: HDV500NV/PV

1 64
Download 64 pages 30.46 Kb
Page 32
Image 32
Lighting pilot for the first time - millivolt

HDV Series Direct Vent Gas Fireplace

OPERATING INSTRUCTIONS - Millivolt

approved leak testing methodLighting pilot for the first time - millivolt Lighting pilot - millivolt PILOT

approved leak testing method

You may check for gas leaks with the following methods only:

Soap and water solution

An approved leak testing spray

WARNING

If using a soap and water solution to test for leaks, DO NOT spray solution onto control body.

• Electronic sniffer

DANGER

Never check for gas leak

 

 

with open flame!

 

 

Check for gas leaks in each of the following locations:

NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.

Pipe from the gas supply line connection to the gas valve

Burner connections

• Field made joints / gas shutoff valve

Pilot

Factory made joints

Each joint or connection

All joints on valve and control body

Lighting pilot - millivolt Manual backgroundManual background

1.Depress and turn knob counterclockwise Manual background to pilot position.

2.Depressfullyandholdpilotgasknob.Depresspiezo ignitor as many times as needed to ignite the pilot. Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn.

If the pilot does not stay lit, repeat steps 1 and 2.

 

O

T

N

 

O

 

L

 

I

 

P

 

 

F

 

F

 

O

PILOT

Figure 45 - Pilot Position

32