System Port Numbers

Only one System Port Number for all BMRs in the database can be stored and modified per system. This is done under the heading “Port Number” in the Message Router table. When entering a Port Number it must fall within the range from 1024 to 65535.

Note: For selecting port numbers in a SmartZone OmniLinktrunking system, refer to system documentation.

Note: Administrators should leave the default System Port Number as is unless there is a port conflict with another application.

Install Inbound Event Display

1.Shut down the Console Database Manager (CDM).

2.Place the Inbound Event Display CD ROM in the CDM PC.

3.Locate and double-click the IEDsetup.exe file to complete the installation. Rebooting again is not required.

4.Restart the CDM.

Configure Console Database Manager (CDM) for Inbound Event Display

1.Verify/Add Radio Message and/or Radio Status capabilities to all resources that will be displayed in Inbound Event Display. Radio Message needs to be added to the resource in the CDM if the user wants to monitor radio messages on the resource. Radio Status needs to be added to the resource in the CDM if a user wants to monitor radio status codes on the resource. Radio Status and Radio Message are not supported on all system types. Please consult the system planner for appropriate usage.

2.Add the Event Status and Event Display capabilities to all operator positions that will be running Inbound Event Display .

Refer to the CDM User’s Guide for details on adding capabilities.

Install Broadcast Message Router

6880801D90-D

4-3

Page 43
Image 43