Motorola DSR-6400 Modulation Menu, Mode Field, Default DCII-AUTO, Symbol / Code / Format Fields

Models: DSR-6400

1 106
Download 106 pages 42.35 Kb
Page 35
Image 35
Modulation Menu

Modulation Menu

This menu is not available when the Manual Tune menu has the Input field set to ASI In or GigE In. That option is described on page 32.

This menu, together with the Manual Tune menu, allows the user to initially acquire a DigiCipher II signal. Press the  buttons until the MODULATION menu appears. Press ENTER to continue.

MODULATION Mode

Default: DCII-AUTOSymbol / Code / Format FieldsDefault: 19.51 3/4 Comb EDCII-AUTO

When the DCII-MAN option is selected, the user must also specify a Symbol/Code/Format combination. When the Mode field is set to DVBS2, the user must also specify a Symbol Rate (Msps).

MODULATION

Mode

Symbol

E

DVBS2

30.000000

MODULATION

Mode

Symbol

E

8PSK-TC

01.000000

MODULATION

Mode

Symbol

E

DVB-MAN

01.000000

MODULATION Mode

Sym

Code Format

E

DCII-MAN

19.51

3/4 Comb

Mode Field

Default: DCII-AUTO

Press the4button until the cursor is at the Mode label, and press ENTER to move into the field. Press the  buttons to display the options: DCII-AUTO, DCII-MAN, or DVBS2. Select a mode and press ENTER to exit the field.

Note: In order to receive a DVB-S2 modulated carrier, the unit must be set to DVBS2 mode and the correct Symbol Rate (Msps) must be entered in the Symbol field. In DCII-MAN mode, the correct Symbol Rate (Msps) must be entered in the Sym field, Code field, and Format field. If DCII-AUTO is selected, the unit searches through all available DC-II Symbol/Code/Format combinations to acquire a signal and then remains locked on that signal.

Symbol / Code / Format Fields

Default: 19.51 3/4 Comb

These three field are not available when the Mode field is set to DCII-AUTO. If the Mode field is set to DCII-MAN, press the 4button until the cursor is at the Sym label and press ENTER to move into the field. Use the  buttons to scroll through the combinations. Each time a  button is pressed, the unit provides a three-field combination for the Sym field, Code field, and Format field. Select the combination provided by your programmer and press ENTER to confirm and exit the field.

If the Mode field is set to DVBS2, the Symbol field can be edited to any value up to 33.000000 by using the arrow buttons (4) to edit each digit.

DSR-6400 Series

35

Page 35
Image 35
Motorola DSR-6400 Modulation Menu, Mode Field, Default DCII-AUTO, Symbol / Code / Format Fields, Default 19.51 3/4 Comb