Once the part is off, turn off the heat, grab the part with a pair of

 

tweezers, and turn off the vacuum pump. Prepare the circuit board for

 

the new component by applying solder paste flux to the solder pads.

 

Position the circuit board under the heat-focus head, lower the head

 

to approximately 1/8”-1/4” (0.3cm-0.6cm) above the board, and turn

 

on the heat. When the solder left behind on the pads reflows, turn off

 

the heat and raise the heat-focus head. Remove the circuit board from

 

the holder and inspect the pads to ensure that the solder has flattened

 

out and that there are no solder shorts. Clean the area with alcohol

 

and a small brush.

 

Once the preparation is complete, place the circuit board back in the

 

circuit board holder. Add solder paste flux to the solder pads and place

 

the new component on the circuit board. Position the heat-focus head

 

over the component and lower it to approximately 1/8”-1/4” (0.3cm-

 

0.6cm) above the carrier. Turn on the heater and wait for the

 

component to reflow.

 

Once the component reflows, raise the heat-focus head and wait

 

approximately one minute for the part to cool. Remove the circuit

 

board and inspect the repair. No cleaning should be necessary.

Shields

 

Removing and Replacing the

will be done with the R-1319, using the same procedure used to

Shields:

remove and replace TSOP and PBGA components.

 

Place the circuit board in the circuit board holder. Select the proper

 

heat focus head and attach it to the heater chimney. Add solder paste

 

flux around the base of the shield. Position the shield under the heat-

 

focus head. Lower the vacuum tip and attach it to the shield by

 

turning on the vacuum pump. Lower the focus head until it is

 

approximately 1/8”-1/4” (0.3cm-0.6cm) above the shield. Turn on the

 

heater and wait until the shield lifts off the circuit board. Once the

 

shield is off, turn off the heat, grab the part with a pair of tweezers, and

 

turn off the vacuum pump. Remove the circuit board from the circuit

 

board holder.

 

To replace the shield, add solder to the shield if necessary, using a

 

micro-tipped soldering iron. Next, rub the soldering iron tip along the

 

edge of the shield to smooth out any excess solder. Use solder wick and

 

a soldering iron to remove excess solder from the solder pads on the

 

circuit board. Place the circuit board back in the circuit board holder.

 

Place the shield on the circuit board using a pair of tweezers. Position

 

the heat-focus head over the shield and lower it to approximately 1/

 

8”-1/4” (0.3cm-0.6cm) above the shield. Turn on the heater and wait

 

for the solder to reflow.

 

Once complete, turn off the heat, raise the heat-focus head, and wait

 

approximately one minute for the part to cool. Remove the circuit

 

board and inspect the repair. No cleaning should be necessary.

RF PA (U105)

The procedure for removing and replacing the RF PA is very similar to

 

the procedure for removing and replacing an PBGA or a TSOP

 

component. But because the device is large, extra heating time is

 

required to flow the pads. And as a result, neighboring components

 

(especially those on the opposite side of the circuit board) will heat,

48

Page 70
Image 70
Motorola HT 1000 service manual Removing and Replacing, Shields