FIELD LEVEL TEST MODES AND PROCEDURES: Signal Quality Error (SQE) Test

8.5Signal Quality Error (SQE) Test

Use this test on a unit having any of the following symptoms: No service failures or poor SQE/RSSI (poor performance in known good coverage area).

Set up the R-2660 for iDEN

Mobile operation, and connect the

unit to the RF IN/OUT

connector. See Figure 7-1 on page

7-3.

Notes:

1.Watch unit for resetting during this procedure.

2.Master reset can be completed on the unit by pressing Menu, Settings, Security.

3.Registration and calls might take over 1 minute to complete.

4.See the Strong Signal Environment section in Chapter 7.

 

 

Connect the regulated battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

eliminator to the unit to be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tested. Set the power supply 7.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vdc.

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

up the unit. Enter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initial Registration mode (see

Fail

 

 

 

Perform the Registra-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pass

Operating

the R-2660.)

Press Start.

 

 

 

 

 

 

 

tion/Call test.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Call

SEQ: 1 thru 6 lights up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

when unit has

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Verify that

 

 

 

registered.

 

 

 

 

 

 

 

 

 

 

 

 

 

the unit can complete an

 

 

 

 

 

 

 

 

 

 

 

SQE Reference Chart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

interconnect call. Press End/Home

 

 

 

 

 

 

 

 

 

 

 

 

Gen

SQE Level

 

until the unit displays Ready. Press Intercon-

 

 

 

 

 

 

 

 

 

 

Fail

 

 

 

 

 

 

 

 

 

 

 

nect (3:1 or 6:1) and Start on the R-2660. Wait

 

for the

 

 

 

-70 dBm

>26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

green LED to light. Press Send on the unit.

 

 

 

 

 

 

 

 

 

-80 dBm

>25

 

 

 

 

 

Note: Leave call connected for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the next test.

 

 

 

 

Perform the

 

 

 

-90 dBm

>23

 

 

 

 

 

 

 

 

 

 

 

 

Registration/Call test.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-100 dBm

>20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pass

Place unit

in Debug Mode (see

Entering Debug Mode). Press

Trace to monitor the SQE & TX level. Fail Press RF in the R-2660 and arrow down to Gen:.

Verify that it is set to -70dBm.

Verify that the SQE is

greater than

26.

Pass

Note: Gen levels in the SQE chart include RF Adapter losses.

Replace the

Main board.

Change

Gen: to -80 dBm, and

check the SQE Reference chart to

 

 

Fail

 

 

 

 

 

 

 

 

 

 

 

 

verify the unit’s SQE per Gen:

 

 

 

 

 

 

 

 

output using the

 

 

 

 

 

 

 

 

 

 

 

chart.

 

 

Unit passed test. Look for

 

 

 

 

 

 

 

 

Pass

 

 

 

 

 

system, coverage, accessory, or

 

 

 

 

 

 

 

software problems.

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the Main board.

64

68P80401P05

Page 79
Image 79