6 - 6 MC70 User Guide
Single Slot USB/Serial Cradle
Table 6-3
Troubleshooting the Single Slot USB/Serial Cradle
Symptom Possible Cause Action
LEDs do not light
when EDA or spare
battery is inserted.
Cradle is not
receiving power. Ensure the power cable is connected securely to both the cradle
and to AC power.
EDA is not seated
firmly in the cradle . Remove and re-insert the EDA into the cradle, ensuring it is
firmly seated.
Spare batte r y is
not seated firmly in
the cradle.
Remove and re-insert the spare battery into the charging slot,
ensuring it is firmly seated.
EDA battery is not
charging. EDA was removed
from cradle or
cradle was
unplugged from
AC power too
soon.
Ensure cradle is receiving power. Ens ure EDA is seated
correctly. Confirm main battery is charging under Start >
Settings > System > Power. The standard capacity battery (1900
mAh) fully charges in less than four hours. The extended
capacity battery (3800 mAh) fully charges in less than eight
hours.
Battery is faulty. Verify that other batteries charge properly. If so, replace the
faulty battery.
The EDA is not
fully seated in the
cradle.
Remove and re-insert the EDA into the cradle, ensuring it is
firmly seated.
Ambient
temperature of the
cradle is too warm.
Move the cradle to an area where the ambient temperature is
between 0oC and 35oC.
Spare batte ry is not
charging. Battery not fully
seated in charging
slot.
Remove and re-insert the spare battery in the cradle, ensuring
it is firmly seated.
Battery inserted
incorrectly. Re-insert the battery so the charging contacts on the battery
align with the contacts on the cradle.
Battery is faulty. Verify that other batteries charge properly. If so, replace the
faulty battery.
Ambient
temperature of the
cradle is too warm.
Move the cradle to an area where the ambient temperature is
between 0oC and 35oC.