Using the MC70 2 - 21

Pick List Mode: This mode allows you to selectively d ecode a bar code when mo re than one bar code is
in the EDA’s field of view. To accomplish this, move the aiming crosshair over the required bar code to
decode only this bar code. This feature is ideal for pick lists containing multiple bar codes and
manufacturing or transport labels containing more than one bar code type (either 1D or 2D).
Image Capture Mode: Use this mode to capture an image within the EDA’s field of view. This is useful
for capturing signatures or images of items like damaged boxes.

Scanning Considerations

Typically, scanning is a simple matter of aim, scan, and decode and a few quick trial effort s master it. However,
consider the followin g to opt imize scanning perf or ma n ce :
Range
Any scanning device decodes we ll over a particular working range — min i mum and ma ximu m d istances
from the bar code. This range varies according to bar code density and scanning device optics.
Scanning within range brings quick and constant decodes; scanning too close or too far away prevents
decodes. Move the scanner closer and further away to find the right working range for the bar codes
being scanned.
Angle
Scanning angle is import ant for promoting quick decodes. When la ser beams reflect directly back into the
scanner from the bar code, this specular reflection can “blind” the scanner.
To avoid this, scan the bar code so that the beam does not bounce directly back. But don’t scan at too
sharp an angle; the scanner needs to collect scattered reflections from the scan to make a successful
decode. Practice quickly shows what tolerances to work within.
Hold the EDA farther away for larger symbols.
Move the EDA closer for symbols with bars that are close together.

Linear Scanning

1. Ensure that a scan enabled application is loaded on the EDA.
2. Aim the scan window at the bar code.
NOTE To enable Pick List Mode, download the Control Panel applet from the Symbol Support site at
http://support.symbol.com. Pick List can also be set in an application using a API command.
NOTE Scanning procedures depend on the app lication and EDA configurati on. An application may use different
scanning procedures from the one listed above.