MultiModemBL User Guide

Appendix E - DIP-Switch Summary

Asynchronous Mode

DIP-Switch

Condition

Effect

#1

UP*

DTR dependent on interface

 

Down

DTR forced On at all times

#2

UP*

Hardware Flow Control

 

Down

Xon/Xoff Flow Control

#3**

2834 Series:

 

 

UP

-15 dB Transmission (leased line)

 

Down*

-9 dB Transmission (leased line)

#3**

1932 and 1432 Series:

 

UP

-10 dB Transmission (leased line)

 

Down*

0 dB Transmission (leased line)

#4

UP*

UUCP Spoofing Off

 

Down

UUCP Spoofing On

#5

UP*

Automatic Answer On

 

Down

Automatic Answer Off

#6

UP*

Max throughput On

 

Down

Max throughput Off

#7

UP

RTS dependent on Interface

 

Down*

RTS forced On at all times

#8

UP

Disable Command Mode

 

Down*

Enable Command Mode

#9

UP

Local Digital Loopback On

 

Down*

Remote Digital Loopback On

#10

UP*

Dial-Up Operation

 

Down

Leased Line Operation

#11

UP

"AT" Responses

 

Down*

Multi-Tech Responses

#12

UP

Synchronous Mode On

 

Down*

Asynchronous Mode On

*Factory Default Setting

**Not applicable in BLK models

140

Page 140
Image 140
Multi-Tech Systems BL-Series manual Appendix E DIP-Switch Summary, Asynchronous Mode, 140