Multi-Tech Systems BL-Series manual Receiver Sensitivity, AGC Dynamic Range, Interface, Connectors

Models: BL-Series

1 168
Download 168 pages 5.13 Kb
Page 15
Image 15

 

Chapter 1 - Introduction and Description

 

 

Receiver Sensitivity

 

All models:

-43 dBm under worst case conditions

AGC Dynamic Range

 

All models:

43 dB

Interface

 

All models:

EIA RS-232C/ITU V.24

Connectors

 

BL models:

One DB-25 RS-232C connector; three RJ11 for phone line, dial-up

 

and leased line; power.

BLK models:

One DB-25 RS-232C connector; two BT plugs for dial-up and leased

 

line; power

Diagnostics

 

All models:

Power-on Self Test, Local Analog Loop, Local Digital Loop, Remote

 

Digital Loop, Back-to-Back Test.

Indicators

 

All models:

LEDs for Transmit Data, Receive Data, Carrier Detect, Speed

 

Indicators, Off Hook, Terminal Ready, Error Correction, Fax, and

 

Error

Controls

 

All models:

Toggle switches for Voice/Data with Originate or Answer, Power On/

 

Off; and DIP Switches for various modem options.

Speaker

 

All models:

Speaker for call progress monitoring

Operating Temperature

 

All models:

0° to 50° C (32° to 120° F)

Power Requirements

 

All models:

115 Volts AC, 60Hz, 0.3amp (2-prong outlet-mounted transformer)

 

240V/50Hz optional (International).

Dimensions

 

All models:

6.150" x 9.00" x 1.375"

 

15.6 cm x 22.9 cm x 3.5 cm

Weight

 

All models:

1.6 pounds/0.72 Kg (without transformer)

 

2.6 pounds/1.18Kg (with transformer)

Limited Warranty

 

All models:

Five Years