Multi-Tech Systems BL-Series manual External Transmit Clock Pin 24, XTC, 159

Models: BL-Series

1 168
Download 168 pages 5.13 Kb
Page 159
Image 159

Appendix J - RS-232C Interface Specifications

External Transmit Clock - Pin 24, XTC

Direction: to modem

Supplies the same function as transmit clock on Pin 15.

Terminal Busy (Out of Service) - Pin 25, OOS

Direction: to modem

The Terminal Busy (OOS) circuit is not defined in the RS-232C standard, but is used by us and most manufacturers to make the phone lines busy to incoming phone calls. Pin 25 is not normally connected to the RS-232C interface when shipped from the factory; it can be ordered connected as an option. If pin 25 is connected and is brought high, the modem will be placed Off Hook, and busy to incoming calls.

159

Page 159
Image 159
Multi-Tech Systems BL-Series manual External Transmit Clock Pin 24, XTC, Terminal Busy Out of Service Pin 25, OOS, 159