E AT Command Summary
CommPlete Communications Server 79
Command Values Description
Inn = 0, 1, 2, Inquire Product Codes
or 5 I0 Request modem ID #.
I1 Request firmware revision #.
I2 Request modem description.
I5 Request DSP version.
#Ixx = password Enter Login Password
Password is case sensitive.
#I=xx = password Store Login Password
Password must be 6–10 characters long, and may
consist of any keyboard characters.
Lnn = 0, 5–11 List Commands
L List stored telephone numbers.
L5 List current operating parameters.
L6 List current S-register values.
L7 List additional parameters.
L8 List online diagnostic parameters.
L9 List line probe signal strength data.
L10 List line probe signal to noise ratio.
L11 List line probe noise data.
Note: To use L9, L10, or L11 when online, you must
first escape to command mode by typing
+++ATLn<CR> (for n type 9, 10, or 11). Type ATO to
return on line.
#Lnn = 0, 1, 2, 3, V.42 Error Correction Mode
or 8 *** #L0 Modems negotiate V.42 mode.
#L1 MNP on and LAP-M off (originate mode only).
#L2 LAP-M on and MNP off (originate mode only).
#L3 Disable detection phase and go directly to LAP-M.
Mnn = 0, 1, 2, Modem Speaker Control
or 3 M0 Modem speaker always off.
*** M1 Modem speaker on until carrier signal detected.
M2 Modem speaker always on.
M3 Monitor speaker on during dialing, off during
handshaking.