MultiModemII User Guide
Command: #CID=n Caller ID | |
Values: | n = 0, 1, or 2 |
Default: | 0 |
Description: | Enables or disables Caller ID recognition and reporting. |
#CID=0 | Disables Caller ID. |
#CID=1 | Enables formatted Caller ID reporting of ICLID SDM (Single |
| Data Message) and MDM (Multiple Data Message) packets. |
#CID=2 | Enables unformatted Caller ID reporting of any ICLID packet |
| received after the first RING cycle, including SDM, MDM, or |
| call waiting packets. |
#CID? | Retrieves the current Caller ID mode from the modem. |
#CID=? Returns the mode capabilities of the modem in a list with each | |
| element separated by commas. |
Command: #DBn | Callback Enable/Disable |
Values: | n = 0 or 1 |
Default: | 0 |
Description: | Enables or disables callback security. When callback security is |
| enabled, phone number memory locations |
| dialing and DTR dialing, become unavailable and are replaced |
| by callback security memory locations |
| ber memory locations and their contents are restored when |
| callback security is disabled. |
#DB0 | Disables callback security. |
#DB1 | Enables callback security. |
Command: $SBn Serial Port Baud Rate
Values: | n = speed in bits per second | |
Default: | 57600 | |
Description: $SB300 | Set serial port to 300 bps. | |
| $SB1200 | Set serial port to 1200 bps. |
| $SB2400 | Set serial port to 2400 bps. |
| $SB4800 | Set serial port to 4800 bps. |
| $SB9600 | Set serial port to 9600 bps. |
| $SB19200 | Set serial port to 19200 bps. |
| $SB38400 | Set serial port to 38400 bps. |
| $SB57600 | Set serial port to 57600 bps. |
| $SB115200 Set serial port to 115200 bps. | |
| $SB230400 Set serial port to 230400 bps. | |
Command: +++AT<CR> | Escape Sequence | |
Values: | n/a |
|
Description: | Puts the modem in command mode (and optionally issues a | |
| command) while remaining online. Type +++AT and up to ten | |
| command characters, and then press ENTER. Used mostly to is- | |
| sue the | |
48