Multi-Tech Systems MT5600BA, MT5600BL manual S32

Models: MT5600BA MT5600BL

1 118
Download 118 pages 61.79 Kb
Page 58
Image 58

MultiModemII User Guide

Register

Unit

Range

Default

Description

 

S13

decimal

0, 1–127

42 (*)

Sets the ASCII code for the remote configu-

 

 

 

 

ration escape character. ATS13=0&W dis-

 

 

 

 

ables remote configuration.

S15

minutes

10–255

30

Sets the length of time the modem waits

 

 

 

 

after making a dial-up connection before it

 

 

 

 

checks the lease line for restoral.

S17

minutes

0–255

1

Sets the length of time the modem waits af-

 

 

 

 

ter after a lease line fails before it attempts a

 

 

 

 

dial-up connection.

S18

seconds

0–255

0

Sets the number of seconds that the modem

 

 

 

 

conducts an &T test before it returns to the

 

 

 

 

command mode. If the value is zero, the test

 

 

 

 

must be terminated from command mode

 

 

 

 

by issuing an &T0 or H command. When

 

 

 

 

S18 is non-zero, the modem returns the OK

 

 

 

 

message upon test termination.

S24

seconds

0–255

0

Sets the number of seconds that the modem

 

 

 

 

operates in normal mode with no detected

 

 

 

 

telephone or serial port activity before it

 

 

 

 

enters low-power sleep mode. The timer is

 

 

 

 

reset upon any serial port or telephone line

 

 

 

 

activity.

S25

10 ms

0–255

5

Sets the length of time that the modem

 

(async)

 

 

ignores DTR while taking the action specified

 

1 ms

 

 

by &D.

 

(sync)

 

 

 

 

S26

10 ms

0–255

1

When &R0 is commanded, sets the time

 

 

 

 

after detecting an OFF-to-ON transition on

 

 

 

 

RTS before the modem turns CTS ON.

 

 

 

 

Applies to synchronous operation only.

S29

10 ms

0–255

70

Sets the length of time that the modem goes

 

 

 

 

on-hook when it encounters a flash dial

 

 

 

 

modifier (!) in the dial string.

S30

10 ms

0, 1–255

0

Sets the length of time that the modem

 

 

 

 

waits before disconnecting when no data is

 

 

 

 

sent or received. A value of zero disables

 

 

 

 

the timer. Applies to asynchronous opera-

 

 

 

 

tion only.

S32

decimal

0–255

17

Sets the ASCII code for the XON character.

S33

decimal

0–255

19

Sets the ASCII code for the XOFF character.

S35

decimal

0–1

0

0 disables, 1 enables the V.25 data calling

 

 

 

 

tone, which allows remote data/fax/voice

 

 

 

 

discrimination.

50

Page 58
Image 58
Multi-Tech Systems MT5600BA, MT5600BL manual S32