Multi-Tech Systems MT5600BA, MT5600BL Data Terminal Ready DTR Control, Error Correction Modes

Models: MT5600BA MT5600BL

1 118
Download 118 pages 61.79 Kb
Page 46
Image 46

MultiModemII User Guide

Command:

&Dn

 

Data Terminal Ready (DTR) Control

Values:

 

 

n = 0, 1, 2, or 3

Default:

 

2

Description:

 

 

This command interprets the high to low transition of the DTR

 

 

 

signal sent by the computer according to the supplied param-

 

 

 

eter. The action taken depends on the current &Q setting.

 

&D0

 

&Q0, &Q5, &Q6: DTR is ignored (assumed high). Allows op-

 

 

 

eration with computers that do not provide DTR.

 

 

 

&Q1, &Q4: DTR drop causes the modem to hang up. Autoan-

 

 

 

swer is not affected.

 

 

 

&Q2, &Q3: DTR drop causes the modem to hang up. Autoan-

 

 

 

swer is inhibited.

 

&D1

 

&Q0, &Q1, &Q4, &Q5, &Q6: DTR drop is interpreted by the

 

 

 

modem as if the asynchronous escape sequence had been en-

 

 

 

tered. The modem returns to asynchronous command state

 

 

 

without disconnecting.

 

 

 

&Q2, &Q3: DTR drop causes the modem to hang up. Autoan-

 

 

 

swer is inhibited.

 

&D2

 

&Q0&Q6: DTR drop causes the modem to hang up. Autoan-

 

 

 

swer is inhibited.

 

&D3

 

&Q0, &Q1, &Q4, &Q5, &Q6: DTR drop causes the modem to

 

 

 

perform a soft reset as if the Z command were received. The &Y

 

 

 

setting determines which profile is loaded.

 

 

 

&Q2, &Q3: DTR drop causes the modem to hang up. Autoan-

 

 

 

swer is inhibited.

 

 

 

&Q5 or &Q6 and +FCLASS=1 or +FCLASS=2: Same as for &Q0.

Command:

&En

 

V.42 Error Correction Modes

Values:

 

 

n = 0, 1, or 2

Default:

 

1

Description:

&E0

 

V.42 non-error correction mode (V.42 disabled).

 

&E1

V.42 auto-reliable mode.

 

&E2

V.42 reliable mode (V.42 enabled).

Command:

&En

 

Modem-Initiated Flow Control

Values:

 

 

n = 3, 4, or 5

Default:

 

4

Description:

&E3

 

Flow control disabled.

 

&E4

CTS/RTS hardware flow control.

 

&E5

XON/XOFF software flow control.

 

 

 

 

 

 

 

Note: See also the &K command.

 

 

 

 

Command:

&Fn

 

Load Factory Settings

Values:

 

 

n = 0 or 1

Default:

 

None

Description:

&F0

 

Load factory configuration 0.

 

&F1

Load factory configuration 1.

 

 

 

 

 

 

 

Note: See also the Z command.

 

 

 

 

38

Page 46
Image 46
Multi-Tech Systems MT5600BA manual Data Terminal Ready DTR Control, Error Correction Modes, Modem-Initiated Flow Control