Register

Unit

Range

Default

Description

 

 

 

 

 

attempt to deliver data in the buffer until

 

 

 

 

the connection is lost or the data is delivered.

S46

decimal

136, 138

138

Enables or disables data compression:

 

 

 

 

136

Error correction without compression.

 

 

 

 

138

Error correction with compression.

S48

decimal

0, 7, 128

7

Enables or disables LAPM negotiation. An

 

 

 

 

invalid value is treated as a 128 value.

 

 

 

 

0

 

Disables negotiation and proceeds with

 

 

 

 

 

 

LAPM.

 

 

 

 

7

 

Enables negotiation.

 

 

 

 

128

 

Disables negotiation and proceeds at

 

 

 

 

 

 

once with the fallback action specified

 

 

 

 

 

 

in S36. Can be used to force MNP.

S86

decimal

0, 4, 5, 9,

n/a

When the modem issues a NO CARRIER

 

 

12, 13, 14

 

result code, a value is written to this register

 

 

 

 

to help determine the reason for the failed

 

 

 

 

connection. S86 records the first event that

 

 

 

 

contributes to a NO CARRIER message. Use

 

 

 

 

the S86? command to read the value.

 

 

 

 

0

 

Normal disconnect; no error occurred.

 

 

 

 

4

 

Loss of carrier.

 

 

 

 

5

 

V.42 negotiation failed to detect an error-

 

 

 

 

 

 

correction modem at the other end.

 

 

 

 

9

 

The modems could not find a common

 

 

 

 

 

 

protocol.

 

 

 

 

12

 

Normal disconnect initiated by the

 

 

 

 

 

 

remote modem.

 

 

 

 

13

 

Remote modem does not respond after

 

 

 

 

 

 

10 retransmissions of the same message.

 

 

 

 

14

 

Protocol violation.

S95

decimal

0–15

0

The bits in this register can be set to over-

 

 

 

 

ride some of the W command options. A bit

 

 

 

 

set to a 1 in this register enables the corre-

 

 

 

 

sponding result code regardless of the W

 

 

 

 

setting.

 

 

 

 

Bit 0 CONNECT result code indicates

 

 

 

 

 

 

DCE speed instead of DTE speed.

 

 

 

 

Bit 1 Append /ARQ to CONNECT XXX

 

 

 

 

 

 

result code in error-correction mode.

 

 

 

 

Bit 2 Enable CARRIER XXXX result code.

 

 

 

 

Bit 3 Enable PROTOCOL XXXX result code.

 

 

 

 

Bit 4

Reserved.

 

 

 

 

Bit 5 Enable COMPRESSION result code.

 

 

 

 

Bit 6

Reserved.

 

 

 

 

Bit 7

Reserved.

52

Page 60
Image 60
Multi-Tech Systems MT5600BA, MT5600BL manual S46