Multi-Tech Systems MT5634SMI V.34, MT5634SMI V.92 manual Mod value Valid maxrate values bps

Models: MT5634SMI V.34 MT5634SMI V.92

1 136
Download 136 pages 25.71 Kb
Page 23
Image 23

Chapter 1 – AT Commands, S-Registers and Result Codes

max_rate An optional number that specifies the highest rate at which the modem may establish an upstream (transmit) connection. The value is decimal coded in units of bps, for example, 33600 specifies the highest rate to be 33600 bps.

0 Maximum rate determined by the modulation selected in mod (default).

300–33600Maximum rate value limited by the modulation selected in mod. For valid max_rate values for each mod value, see the following table.

mod value

Valid max_rate values (bps)

 

 

V92, V90, V34

31200, 28800, 26400, 24000, 21600,19200, 16800,

 

14400, 12000, 9600, 7200, 4800, 2400

V32B

19200, 16800, 14400, 12000, 9600, 7200, 4800

V32

14400, 12000, 9600, 7200, 4800

V22B

2400

V22, V23C, Bell212A

1200

V21, Bell103

300

max_rx_rate An optional number that specifies the highest rate at which the modem may establish a downstream (receive) connection. The value is decimal coded in units of bps, e.g., 28800 specifies the highest rate to be 28800 bps.

0 Maximum rate determined by the modulation selected in mod (default).

300–56000 Maximum rate value limited by the modulation selected in mod. See “Possible rates” in the mod table.

Command:

+PCW=n

Call Waiting Enable

Values:

 

n = 0, 1, or 2

Default:

 

2

 

Description:

 

Controls the action to be taken upon detection of a call waiting tone in V.92

 

 

mode. Values specified by this command are not modified when an AT&F

 

 

command is issued.

 

 

+PCW=0

Toggles V.24 Circuit 125 and collects Caller ID if enabled by

 

 

 

+VCID

 

 

+PCW=1

Hangs up

 

 

+PCW=2

Ignores V.92 call waiting

 

 

+PCW=?

Displays the allowed values

 

 

+PCW?

Displays the current value

Command:

+PIG=n

PCM Upstream Ignore

Values:

 

n = 0 or 1

 

Default:

 

1

 

Description:

 

Controls the use of PCM upstream during V.92 operation. PCM upstream

 

 

allows faster upload speeds to a V.92 server.

 

 

+PIG=0

Disables PCM upstream

 

 

+PIG=1

Enables PCM upstream

 

 

+PIG=?

Displays the allowed values

 

 

+PIG?

Displays the current value

Command:

+PMH=n

Modem on Hold Enable

Values:

 

n = 0 or 1

 

Default:

 

1

 

Description:

 

Controls if modem on hold procedures are enabled during V.92 operation.

 

 

Normally controlled by a modem on hold program. Values specified by this

 

 

command are not modified when an AT&F command is issued.

 

 

+PMH=0

Enables V.92 modem on hold

 

 

+PMH=1

Disables V.92 modem on hold

 

 

+PMH=?

Displays the allowed values

 

 

+PMH?

Displays the current value

Multi-Tech Systems, Inc. SocketModem MT5634SMIxx Reference Guide (S000263C)

23

Page 23
Image 23
Multi-Tech Systems MT5634SMI V.34, MT5634SMI V.92 Mod value Valid maxrate values bps, Command +PCW=n Call Waiting Enable

MT5634SMI V.34, MT5634SMI V.92 specifications

The Multi-Tech Systems MT5634SMI is a versatile and robust external modem designed to cater to a variety of communication needs. As a V.92/V.34 standard modem, it provides reliable and efficient data connections for both home and business users. Its unique blend of features and technologies makes it an excellent choice for users looking to achieve optimal performance in their data transmission.

One of the standout features of the MT5634SMI is its support for the V.92 standard, which offers faster throughput and enhanced performance compared to prior standards. With V.92, users can experience download speeds of up to 56 Kbps and upload speeds reaching 48 Kbps. This improved speed is particularly beneficial for users who frequently download large files or engage in data-intensive activities.

The modem also includes the V.34 technology, which further enhances its capabilities by improving connection reliability and data integrity over various line conditions. Utilizing advanced error correction and data compression techniques, the V.34 modem ensures a smoother and faster communication experience. This makes it ideal for users in areas with fluctuating line quality or those who require stable connections for online conferencing or telecommuting.

In terms of form factor, the MT5634SMI is an external modem, which allows for easy installation and portability. Its compact design ensures it can fit into any workspace without taking up much room or adding clutter. The modem connects to computers via standard serial ports, making it compatible with a wide range of devices, both modern and legacy.

Additional features of the MT5634SMI include built-in diagnostics to assist troubleshooting and ensure smooth operation. It supports multiple operating environments, catering to users operating on various systems, providing versatility for both home and office settings. The modem's compatibility with popular operating systems guarantees that users can easily integrate it into their existing setups without a hassle.

In conclusion, the Multi-Tech Systems MT5634SMI V.92/V.34 modem stands out as a reliable choice for anyone needing high-speed internet connectivity. With its strong feature set, enhanced technologies, and user-friendly design, it is an asset for enhancing communication and data transfer capabilities. Whether for personal use or business applications, the MT5634SMI delivers performance and reliability, making it a valuable addition to any technology arsenal.