Chapter 1 – AT Commands, S-Registers and Result Codes

Chapter 1 – AT Commands, S- Registers and Result Codes

Introduction

The AT commands are used to control the operation of your modem. They are called AT commands because the characters AT must precede each command to get the ATtention of the modem.

AT commands can be issued only when the modem is in command mode or online command mode.

The modem is in command mode whenever it is not connected to another modem.

The modem is in data mode whenever it is connected to another modem and ready to exchange data. Online command mode is a temporary state in which you can issue commands to the modem while connected to another modem.

To put the modem into online command mode from data mode, you must issue an escape sequence (+++) followed immediately by the AT characters and the command, e.g., +++ATH to hang up the modem. To return to data mode from online command mode, you must issue the command ATO.

To send AT commands to the modem you must use a communications program, such as the HyperTerminal applet in Windows 98 and NT 4.0, or some other available terminal program. You can issue commands to the modem either directly, by typing them in the terminal window of the communications program, or indirectly, by configuring the operating system or communications program to send the commands automatically. Fortunately, communications programs make daily operation of modems effortless by hiding the commands from the user. Most users, therefore, need to use AT commands only when reconfiguring the modem, e.g., to turn auto answer on or off.

The format for entering an AT command is ATXn, where X is the command and n is the specific value for the command, sometimes called the command parameter. The value is always a number. If the value is zero, you can omit it from the command; thus, AT&W is equivalent to AT&W0. Most commands have a default value, which is the value that is set at the factory. The default values are shown in the “AT Command Summary” (See below).

You must press ENTER (it could be some other key depending on the terminal program) to send the command to the modem. Any time the modem receives a command, it sends a response known as a result code. The most common result codes are OK, ERROR, and the CONNECT messages that the modem sends to the computer when it is connecting to another modem. See a table of valid result codes at the end of this chapter.

You can issue several commands in one line, in what is called a command string. The command string begins with AT and ends when you press ENTER. Spaces to separate the commands are optional; the command interpreter ignores them. The most familiar command string is the initialization string, which is used to configure the modem when it is turned on or reset, or when your communications software calls another modem.

Multi-Tech Systems, Inc. SocketModem MT5634SMIxx Reference Guide (S000263C)

5

Page 5
Image 5
Multi-Tech Systems MT5634SMI V.34, MT5634SMI V.92 manual AT Commands, S- Registers and Result Codes, Introduction

MT5634SMI V.34, MT5634SMI V.92 specifications

The Multi-Tech Systems MT5634SMI is a versatile and robust external modem designed to cater to a variety of communication needs. As a V.92/V.34 standard modem, it provides reliable and efficient data connections for both home and business users. Its unique blend of features and technologies makes it an excellent choice for users looking to achieve optimal performance in their data transmission.

One of the standout features of the MT5634SMI is its support for the V.92 standard, which offers faster throughput and enhanced performance compared to prior standards. With V.92, users can experience download speeds of up to 56 Kbps and upload speeds reaching 48 Kbps. This improved speed is particularly beneficial for users who frequently download large files or engage in data-intensive activities.

The modem also includes the V.34 technology, which further enhances its capabilities by improving connection reliability and data integrity over various line conditions. Utilizing advanced error correction and data compression techniques, the V.34 modem ensures a smoother and faster communication experience. This makes it ideal for users in areas with fluctuating line quality or those who require stable connections for online conferencing or telecommuting.

In terms of form factor, the MT5634SMI is an external modem, which allows for easy installation and portability. Its compact design ensures it can fit into any workspace without taking up much room or adding clutter. The modem connects to computers via standard serial ports, making it compatible with a wide range of devices, both modern and legacy.

Additional features of the MT5634SMI include built-in diagnostics to assist troubleshooting and ensure smooth operation. It supports multiple operating environments, catering to users operating on various systems, providing versatility for both home and office settings. The modem's compatibility with popular operating systems guarantees that users can easily integrate it into their existing setups without a hassle.

In conclusion, the Multi-Tech Systems MT5634SMI V.92/V.34 modem stands out as a reliable choice for anyone needing high-speed internet connectivity. With its strong feature set, enhanced technologies, and user-friendly design, it is an asset for enhancing communication and data transfer capabilities. Whether for personal use or business applications, the MT5634SMI delivers performance and reliability, making it a valuable addition to any technology arsenal.