Chapter 4 – Voice Commands

Command:

+VNH=<hook><Enter>

Automatic Hang-Up Control

Values:

0, 1, 2, 3 through 255

 

Result Codes:

OK if command accepted; ERROR if parameter out of range.

Description:

The +VNH command causes the modem to enable or disable automatic hang ups to a

 

varying degree when in Data mode or Fax mode, as shown below:

 

+VNH=0

Enable automatic hang-ups as is normal in other non-Voice modes (such

 

 

as hanging up the phone when the modem does not detect a data carrier

 

 

within a given time interval).

 

+VNH=1

Disable automatic hang-ups in other non-Voice modes

 

+VNH=2

Disable automatic hang-ups in other non-Voice modes. The modem

 

 

performs only a "logical" hang up (i.e., returns the OK result code).

 

+VNH=3-255 Reserved for future standards

Command:

+FMI?<Enter>

Report Manufacturer's ID

Values:

N/A

 

 

Default:

N/A

 

 

Result Codes:

Only unsolicited result codes (not the standard AT -type OK result code)

Description:

The + FMI? command causes the modem to report text consisting of a single line with the

 

modem manufacturer's name (e.g., LucentData/Fax/Voice), and our address, phone, and

 

fax numbers.

 

 

Command:

+FMM?<Enter>

Report Product ID

Result Codes:

Only unsolicited result codes (not the standard AT-type OK result code)

Description:

The +FMM command causes the modem to report text consisting of a single line with the

 

modem's name (e.g., SocketModem).

Command:

+FMR?<Enter>

Report Version Level

Result Codes:

OK or ERROR

 

Description:

The +FMR command causes the modem to report the firmware version number and/or a

 

date code (e.g., Vs. 2.07 – 2/4/95).

Command:

+FLO=<method><Enter>

Select Flow Control Method

Values:

0, 1, 2, 3–255Result Codes: OK, or ERROR

Description:

The +FLO? command lets you select the method of flow control provided and used by

 

the modem. If +FLO=0, some other method (such as credit flow control) is used. The

 

Xon-Xoff method is required. Xon is the ASCII character <DC1> (11 hex). Xoff is the

 

ASCII character >DC3> (13 hex). CCITT V.24 circuits 106 and 133 are optional flow

 

control methods. If circuits 106 and 133 are not used (+FLO<>2), then circuit 106 is held

 

On whenever +FCLASS=8. In Voice mode, circuit 105 has no effect on the state of

 

transmitted data. (Circuit 133 normally reverts to use as circuit 105 (RTS) when not used

 

for Flow Control.)

 

 

+FLO=0

Disable Xon-Xoff and 133/105 flow control

 

+FLO=1

Enable Xon-Xoff flow control in either direction

 

+FLO=2

Enable CCITT Circuit 133 for flow control of the modem by the PC; use

 

 

CCITT Circuit 106 for flow control of the PC by the modem.

 

+FLO=3-255

Reserved for future standards

Command:

VIP

Initialize Voice Parameters

Values:

0 (optional)

 

 

Description:

The +VIP command causes the modem to initialize all Voice parameters to the factory

 

default settings. This command has the same effect as if the PC had issued commands

 

for the individual parameter settings. The +VIP command has no effect on the +FCLASS

 

setting. The optional command +VIP=0 <Enter> provides a selection of default profiles.

Multi-Tech Systems, Inc. SocketModem MT5634SMIxx Reference Guide (S000263C)

107

Page 107
Image 107
Multi-Tech Systems MT5634SMI V.34 Command +VNH=hookEnter Automatic Hang-Up Control, Command +FMM?Enter Report Product ID

MT5634SMI V.34, MT5634SMI V.92 specifications

The Multi-Tech Systems MT5634SMI is a versatile and robust external modem designed to cater to a variety of communication needs. As a V.92/V.34 standard modem, it provides reliable and efficient data connections for both home and business users. Its unique blend of features and technologies makes it an excellent choice for users looking to achieve optimal performance in their data transmission.

One of the standout features of the MT5634SMI is its support for the V.92 standard, which offers faster throughput and enhanced performance compared to prior standards. With V.92, users can experience download speeds of up to 56 Kbps and upload speeds reaching 48 Kbps. This improved speed is particularly beneficial for users who frequently download large files or engage in data-intensive activities.

The modem also includes the V.34 technology, which further enhances its capabilities by improving connection reliability and data integrity over various line conditions. Utilizing advanced error correction and data compression techniques, the V.34 modem ensures a smoother and faster communication experience. This makes it ideal for users in areas with fluctuating line quality or those who require stable connections for online conferencing or telecommuting.

In terms of form factor, the MT5634SMI is an external modem, which allows for easy installation and portability. Its compact design ensures it can fit into any workspace without taking up much room or adding clutter. The modem connects to computers via standard serial ports, making it compatible with a wide range of devices, both modern and legacy.

Additional features of the MT5634SMI include built-in diagnostics to assist troubleshooting and ensure smooth operation. It supports multiple operating environments, catering to users operating on various systems, providing versatility for both home and office settings. The modem's compatibility with popular operating systems guarantees that users can easily integrate it into their existing setups without a hassle.

In conclusion, the Multi-Tech Systems MT5634SMI V.92/V.34 modem stands out as a reliable choice for anyone needing high-speed internet connectivity. With its strong feature set, enhanced technologies, and user-friendly design, it is an asset for enhancing communication and data transfer capabilities. Whether for personal use or business applications, the MT5634SMI delivers performance and reliability, making it a valuable addition to any technology arsenal.