SocketModem
SocketModem Reference Guide
Contents
103
AT Commands, S- Registers and Result Codes
Introduction
AT Command Summary
Command Description
AT Commands, S-Registers and Result Codes
# Cbfr
AT Commands
Command Dial
Command DS=y Dial Stored Telephone Number
Command Echo Command Mode Characters
Command Echo Online Data Characters
Command Information Request
Command Monitor Speaker Mode
Command Modulation Handshake
Command On Return Online to Data Mode
Command Sr=n Set Register Value
Command Sr? Read Register Value
Command Tone Dialing
Command Result Code Format
Command Data Carrier Detect DCD Control
Command Data Terminal Ready DTR Control
Command XON/XOFF Pacing Control
Command Load Factory Settings
Command Leased Line Operation
Command Pulse Dial Make-to-Break Ratio Selection
Command Asynchronous Communications Mode
Command Data Set Ready DSR Control
Command Display Current Settings
Command Store Current Configuration
Command Zy=x Store Dialing Command
Command \An Select Maximum MNP Block Size
Command \Kn Break Control
Command \Nn Error Correction Mode Selection
Command \Qn Flow Control Selection
Command \Tn Inactivity Timer
Command \Vn Protocol Result Code
Command \Xn XON/XOFF Pass-Through
Command Data Calling Tone
Command Adaptive Answer Result Code Enable
Command Fallback and Fall Forward Control
Command Direct Connect Enable
Command Cisco Configuration
Command Command Speed Response
Command $RPn Ring Priority vs. AT Command Priority
Command $SBn Serial Port Baud Rate
Command +VDR=x, y Distinctive Ring Report
+VDR?
Command #CBAn Callback Attempts
Command #CBDn Callback Delay
Callback Failed Attempts Reset
Command #CBIn Local Callback Inactivity Timer
Command #CBRy Callback Security Reset
Command #CBSn Callback Enable/Disable
Command #Pn Set 11-bit Parity
Command #Sx Enter Setup Password
Escape AT Commands
Command +++ATCR Escape Sequence
Command Atmtsmodemcr Remote Configuration Escape Sequence
S13
Command +MS= Modulation Selection
Commands
Modulation Possible rates bps1
Command +PCW=n Call Waiting Enable
Command +PIG=n PCM Upstream Ignore
Command +PMH=n Modem on Hold Enable
Mod value Valid maxrate values bps
Command +PMHT=n Modem on Hold Timer
Command +PMHR=n Modem on Hold Initiate
Modem Hook Flash
Command +PQC=n Quick Connect Control
Command +VCID=n Caller ID Selection
#CBF?
Description Enters the callback security setup password
Registers
S38
S37
S43
S48
S48=7 S48=128
S89
S108
Result Codes
Terse Verbose Description
112
Fax I/O Processing
DTE-to-Modem Transmit Data Stream
Modem-to-DTE Receive Data Stream
Characters Detected Action Taken
Fax Mode Selection
Fax Origination
Fax Answering
Fax Control Transmission
Fax Control Reception
Fax Data Transmission
Fax Data Reception
Mode Entry Commands
Commands and Parameters
Mode Commands
Command
Mod Modulation Training Modulation Mode and Rate
Transmit Facsimile
Fax Class 1 and Fax Class 1.0 Modulation Modes and Rates
Command +FRM Receive Facsimile
Command FTH Transmit Data with Hdlc Framing
Command +FRH Receive Data with Hdlc Framing
Command +FAR Adaptive Reception Control
Service Class 1 Commands
Command +FCL Carrier Loss Timeout
+FDD
DTE Inactivity Timeout
+FIT
Command +FPR Fixed DTE Rate
Command +FMI? Request Manufacturer Identification
Command +FMM? Request Model Identification
Command +FMR? Request Revision Identification
Command +FLO Flow Control
Examples
Fax Class 1 Calling Sequence Transmitting a Single
Fax Class 1 Answering Sequence Receiving a Single
Send FCS Accept FCS Final frame
Fax Class 2 and 2.0/2.1 Commands
AT Command Implementation
+FCLASS=2.1
AT Command Mode
Modes of Interaction
+Fparameternamevalue
Command Execution Mode
Data Transfer Mode
Page
Fax Parameter DLE Character to Precede Image Data
Commands and Responses Overview
Action Commands
For example AT+FCLASS=2
Depends on the capability to receive set by +FCR
Modem Responses
Class Response description
Parameters for Mandatory Services
Class Mandatory parameter description
Parameters for Optional Services
Class Optional parameter description
Identification Commands
Service Class Indication
Service Class Capabilities
+FCLASS?
Service Class Selection
Request Manufacturer Identification
Request Model Identification
Request Revision Identification
Action Commands
Originate a Call
Answer a Call
ATD
Data Transmission
Post-Page Message Release
+FDT
Class +FET=n
Session Termination
Data Reception
Initialize Facsimile Parameters
Phase a Negotiation Responses
Modem Responses
+FCO
+FCON
Phase B Negotiation Responses
Class +FCS, +FIS, +FTC
+FDCS, +FDIS +FDTC
+FPO
Class +FTI, +FCI, +FPI
+FTSI, +FCSI, +FCIG
Class +FNF, +FNS, +FNC
+FNSF, +FNSS, +FNSC
Report Addressing or Password Strings
Class +FSA, +FPA, +FPW
+FSASUB string
+FPASEP string
+FPS
Phase C Page Reception Responses
+FPTS
Phase D Post Page Responses
Call Termination with Status
+FET
+FHS
Hang-up Status Codes
Class Cause
C0-DF
Parameter Commands
Session Parameters
+FCC=
+FDCC=
+FIS=
+FDIS=
+FCS?
+FDCS?
Session Subparameters
CRLF0-1,0-3,0-4,0-2,0,0,0,0-7,0CRLF
T.30 Session Subparameter Codes
Label Function Class 2.0/2.1 Description
Function Class 2.0/2.1 Description
+FLI
+FLID
+FPI
+FCIG
+FNS
+FLP
+FLPL
+FSP
+FCR
+FBU
+FBUG
Capability to Receive
+FNR
+FAP
Negotiation Reporting
Address & Polling Capabilities
+ FPW = Password string
Addressing & Polling Frames
+ FSA = destination Subaddress string
+ FPA = selective Polling Address string
Procedure Control Parameters
Transfer Status
+FCQ
Copy Quality Checking
+FRQ
+FBADMUL
+FBADLIN
Receive Quality Thresholds
Host Phase C Response Timeout, +FCT
+FPHCTO, Host Phase C Response Time-out
+FAA
Adaptive Answer
Class 2.0/2.1 not supported
+FAXERR
Class 2.0/2.1 +FMS
+FMINSP
Phase C Data Format Parameters
Class 2.0/2.1 +FBO
+FBOR
Class 2.0/2.1 +FEA
Class 2.0/2.1
Format conversion, +FFC
Vertical Resolution Format Conversion +FVRFC
Class 2.0/2.1 Not Applicable
Write syntax +FVRFC=value
Data Compression Format Conversion, +FDFFC
Fax Flow Control, +FLO
Width Format Conversion, +FWDFC
FWDFC=0
FWDFC=1
Set Current Time and Date, AT+FTD
Header Generation, AT+FPH
Miscellaneous Parameters
Buffer Size, +FBS Class 2.1 only
Session Message Report Responses
Report Transmit Hdlc Frames, +FHT
Report Received Hdlc Frames, +FHR
Syntax +FHTtransmitted Hdlc frame octets
Send two pages, 1-D data, no errors Class
Sample Modem Control Sessions
Receive two pages, 1-D data, no errors Class
AT+FCLASS=2.0
Ring
Host Modem Local Modem Remote Station Commands
AT+FCLASS=2.1
Alphabetic List of Commands and Responses
100
101
Ascii Conversion Chart
102
Voice Commands
103
Commands That Change for Voice Mode Support
Voice Commands
Voice S-Register Summary
Voice +V Commands Detail
Voice +V Commands Summary
Command +FCLASS= mode Enter Select Modem Operating Mode
Command +FCLASS=8 Dtmf Detect Detect and Control Dtmf
Touch Tone Signals Digit Low frequency High frequency
AT+FCLASS=8
¾R is Ring
Command +VNH=hookEnter Automatic Hang-Up Control
Command +FMI?Enter Report Manufacturers ID
Command +FMM?Enter Report Product ID
Command +FMR?Enter Report Version Level
Enter Voice Receive State
108
AT+VTS=?
Command +VTS=? Report Frequency Support
109
Command +VGR=gain Set the Gain for Received Voice Samples
Command +VIT=timer Set DTE/DCE Inactivity Timer
Start Voice Transmission Process
110
Code Description
Command +VLS=label Select Analog Source/Destination
111
Command +VRA=interval Set Ring Back Goes Away Timer
Command +VRN=interval Set Ring Back Never Appeared Timer
AT+VLS=?
112
Command +VSD=sds,sdi Set Silence Detection Sensitivity
113
Command +VSM=cml,vsr,scs,sel Select Voice Compression Method
114
Command +VSM=? Report Voice Compression Method
AT+VSM=?
Identifier Description
Lsltcq
Enable report Description
116
Command +VEM=mask Event Reporting and Masking
Command +VDT=enable,report Control Tone Cadence Reporting
117
118
AT+VBT=?
Interface Configuration Commands
119
120
Voice Mode Result Codes
Flow Control
Terse Verbose
Busy Dialtone
Unsolicited Voice Mode Result Codes
Valid Complex Event Report Tags
Tag Description
122
Shielded Code Hex Event Report Description
Voice Mode Shielded Codes
123
Ascii
124
Command Response
Sample Sessions
Sample Rate Selection and Suggested Compression Method
125
126
127
DTE/DCE Interface Rates
128
Remote Configuration
Basic Procedure
Setup
129
Country Code Configuration
Using the Global Wizard Utility
Using AT Commands
Country AT Command Result Code Hexadecimal Decimal
Index
131
Callback Attempts command #CBA
132
133
+FSA
134
+FTH Transmit Data with Hdlc Framing
Parity, setting
135
Procedure Control Parameters
136