Chapter 3 - AT Commands, S-Registers, and Result Codes

Upstream data rates

Upstream V.90 data rates are 4800 to 33,600 bps in 2400 bps increments.

S48=

7, 128

 

S48 sets the LAPM error control and feature negotiation:

 

 

 

S48=7

Negotiation enabled

 

 

 

S48=128

Negotiation disabled. Force

 

 

 

 

immediate fallback options

 

 

 

 

specified in S36

 

 

 

S36=0 or 2, and S48=7

LAPM or hang up

 

 

 

S36=0 or 2 and S48= 128

Do not use

 

 

 

S36=1 or 3, and S48=7

LAPM or async

 

 

 

S36=1 or 3, and S48=128

Async

 

 

 

S36=4 or 6, and S48=7

LAPM, MNP or hang up

 

 

 

S36=4 or 6, and S48=128

MNP or hang up

 

 

 

S36=5 or 7, and S48=7

LAPM, MNP or async

 

 

 

S36=5 or 7, and S48=128

MNP or hang up

S89=

0, 5 - 60 030

S89 sets the Sleep Mode control timer. Specify the number of

 

 

 

seconds of inactivity (no character sent from DTE, no RING) in the

 

 

 

off-line command state before the modem places itself into standby

 

 

 

mode. A value of “0” prevents standby mode. If a number between 1

 

 

 

and 4 is entered for this register, it will set the value to 5.

S109

0--2

1

Sets one of three 56K operating modes:

 

 

 

K56flex mode, V.90 mode, or Auto-mode. S109=2 forces V.90

 

 

 

connections for testing purposes, etc. S109 sets the 56K operating

 

 

 

mode as shown below:

 

0 = V.90 disabled

1 = K56flex or V.90 (Dual mode enabled)

2 = V.90 only (K56flex disabled).

MT5634ZLX/E

43

Page 43
Image 43
Multi-Tech Systems MT5634ZLX 2, MT5634ZLXE-T manual MT5634ZLX/E